The current operation strategy for using Saltstone Vault 4 to receive 0.2 Ci/gallon salt solution waste involves pouring a clean grout layer over the radioactive grout prior to initiating pour into another cell. This will minimize the radiating surface area and reduce the dose rate at the vault and surrounding area. The Clean Cap will be used to shield about four feet of Saltstone poured into a Z-Area vault cell prior to moving to another cell. The minimum thickness of the Clean Cap layer will be determined by the cesium concentration and resulting dose levels and it is expected to ... continued below

Creation Information

Langton, C April 22, 2005.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Author

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

The current operation strategy for using Saltstone Vault 4 to receive 0.2 Ci/gallon salt solution waste involves pouring a clean grout layer over the radioactive grout prior to initiating pour into another cell. This will minimize the radiating surface area and reduce the dose rate at the vault and surrounding area. The Clean Cap will be used to shield about four feet of Saltstone poured into a Z-Area vault cell prior to moving to another cell. The minimum thickness of the Clean Cap layer will be determined by the cesium concentration and resulting dose levels and it is expected to be about one foot thick based on current calculations for 0.1 Ci Saltstone that is produced in the Saltstone process by stabilization of 0.2 Ci salt solution. This report documents experiments performed to identify a formulation for the Clean Cap. Thermal transient calculations, adiabatic temperature rise measurements, pour height, time between pour calculations and shielding calculations were beyond the scope and time limitations of this study. However, data required for shielding calculations (composition and specific gravity) are provided for shielding calculations. The approach used to design a Clean Cap formulation was to produce a slurry from the reference premix (10/45/45 weight percent cement/slag/fly ash) and domestic water that resembled as closely as possible the properties of the Saltstone slurry. In addition, options were investigated that may offer advantages such as less bleed water and less heat generation. The options with less bleed water required addition of dispersants. The options with lower heat contained more fly ash and less slag. A mix containing 10/45/45 weight percent cement/slag/fly ash with a water to premix ratio of 0.60 is recommended for the Clean Cap. Although this mix may generate more than 3 volume percent standing water (bleed water), it has rheological, mixing and flow properties that are similar to previously processed Saltstone. The recommended Clean Cap mix generates more bleed water than the reference Saltstone formulation because the specific gravity of water, the carrier fluid, is less than that of the carrier fluid in Saltstone, 1 versus 1.1 to 1.2, respectively. In addition, the development of slurry structure as a result of hydration reactions is slightly slower than in the salt solution slurry. In other words, the Clean Cap mix has a slightly longer gel time. The lower density of the carrier fluid and the slower development of slurry structure, enable more settling to occur (more standing water) in the Clean Cap slurry. Consequently, for the same rheological properties, the Clean Cap slurry will have more bleed water. In an attempt to reduce the bleed water, the water to premix ratio was lowered and dispersants (high range water reducers) were added. Below water to premix ratios of 0.35, little bleed water and settling was observed. However, a low water to premix Clean Cap mix is not recommended because processing has not been demonstrated in the Saltstone facility. The lowest water to premix ratio processed in Z-Area was 0.478 in the last attempt to produce a clean cap. Although this option may provide significant advantages (less bleed water and potentially better flow) process testing in the Saltstone Facility or in a pilot scale facility in conjunction with laboratory testing will be required to demonstrate mixing, pumping and flow properties. Other additives were tested to minimize bleed water. These additives were found to be unsatisfactory in one or more ways and therefore, were not recommended at this time. An air entraining agent and a thickener had some benefit in reducing bleed water but were found too difficult to implement as an additive in the Saltstone facility. Surfactants (air entrainers) added to the mixing water in the hold tank could generate foam as the result of agitation to mix the tank, and the thickener increased the apparent viscosity and yield stress.

Notes

available

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Report No.: WSRC-TR-2005-00158
  • Grant Number: DE-AC09-96SR18500
  • DOI: 10.2172/890170 | External Link
  • Office of Scientific & Technical Information Report Number: 890170
  • Archival Resource Key: ark:/67531/metadc884033

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • April 22, 2005

Added to The UNT Digital Library

  • Sept. 21, 2016, 2:29 a.m.

Description Last Updated

  • Nov. 2, 2016, 1:09 p.m.

Usage Statistics

When was this report last used?

Congratulations! It looks like you are the first person to view this item online.

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Langton, C. Saltstone Clean Cap Formulation, report, April 22, 2005; [Aiken, South Carolina]. (digital.library.unt.edu/ark:/67531/metadc884033/: accessed August 18, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.