In this quarter (Q2 FY06), the DTEM underwent a substantial reconfiguration of its laser systems. The cathode laser system was changed to provide greater numbers of electrons per pulse by lengthening the time duration of the pulse to 30 ns. The greater number of electrons per pulse has allowed us to acquire high quality pulsed images and diffraction patterns. The spatial resolution in the single pulsed image has been measured at better than 20 nm. The diffraction patterns are now more comparable to conventional electron microscope operation. Examples are found in the body of the report. We summarize important achievements ... continued below

Physical Description

PDF-file: 10 pages; size: 1.8 Mbytes

Creation Information

Campbell, G. H. March 29, 2006.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Titles

  • Main Title: Quarterly progress report for Q2 FY06 for Complex Transient Events in Materials Studied Using Ultrafast Electron Probes and Terascale Simulation (FWP SCW0289)
  • Series Title: Fiscal Year 2006

Description

In this quarter (Q2 FY06), the DTEM underwent a substantial reconfiguration of its laser systems. The cathode laser system was changed to provide greater numbers of electrons per pulse by lengthening the time duration of the pulse to 30 ns. The greater number of electrons per pulse has allowed us to acquire high quality pulsed images and diffraction patterns. The spatial resolution in the single pulsed image has been measured at better than 20 nm. The diffraction patterns are now more comparable to conventional electron microscope operation. Examples are found in the body of the report. We summarize important achievements in the following list: (1) Instrument performance and design improvements--(A) The laser system was changed for the cathode photoemission system (75 ns at 1053 nm wavelength converted to 30ns at 211 nm wavelength) to give longer electron pulses at the same current to yield more electrons per pulse. (B) New specimen drive laser constructed. (C) New computer monitored and controlled alignment systems installed for both laser systems to facilitate laser alignment through a user friendly computer interface. (2) Experimental Progress--(A) The spatial resolution of pulsed images was tested by imaging a cross-section of multilayer thin foils with 30 nm and 20 nm periods. Single pulse images were observed to have spatial resolution better than 20 nm. This combination of 20 nm spatial and 30 ns temporal resolution is thought to be highest combined spatial and temporal measurement ever made. (B) The quality of single pulse electron diffraction patterns have been improved to the point where differentiating the HCP from BCC patterns in Ti is substantially easier. The spatial coherence of the electron illumination on the specimen was improved to give much smaller diffraction spots in the pattern.

Physical Description

PDF-file: 10 pages; size: 1.8 Mbytes

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Report No.: UCRL-TR-220327
  • Grant Number: W-7405-ENG-48
  • DOI: 10.2172/891064 | External Link
  • Office of Scientific & Technical Information Report Number: 891064
  • Archival Resource Key: ark:/67531/metadc882107

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • March 29, 2006

Added to The UNT Digital Library

  • Sept. 21, 2016, 2:29 a.m.

Description Last Updated

  • Dec. 7, 2016, 8:03 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 1

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Campbell, G. H. Quarterly progress report for Q2 FY06 for Complex Transient Events in Materials Studied Using Ultrafast Electron Probes and Terascale Simulation (FWP SCW0289), report, March 29, 2006; Livermore, California. (digital.library.unt.edu/ark:/67531/metadc882107/: accessed November 20, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.