We measured the lengths of colliding e{sup +}e{sup -} bunches in the PEP-II B Factory at SLAC using various techniques. First, at several RF voltages and with both single-bunch and multibunch beams, a synchroscan streak camera measured synchrotron emission through a narrow blue filter. With 3.8 MV of RF, the length of a single positron bunch was 12 mm at low current, rising to 13 mm at 1.5 mA and 14.8 mm at 3 mA. The electrons measured 12.2 mm at 16 MV with little current dependence. Both are longer than the expected low-current value of 10 mm (e{sup +}) ... continued below

Physical Description

4 pages

Creation Information

Fisher, Alan S.; Novokhatski, A.; Turner, J.L.; Wienands, U.; Yocky, G.; /SLAC et al. June 10, 2005.

Context

This article is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this article can be viewed below.

Who

People and organizations associated with either the creation of this article or its content.

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this article. Follow the links below to find similar items on the Digital Library.

Description

We measured the lengths of colliding e{sup +}e{sup -} bunches in the PEP-II B Factory at SLAC using various techniques. First, at several RF voltages and with both single-bunch and multibunch beams, a synchroscan streak camera measured synchrotron emission through a narrow blue filter. With 3.8 MV of RF, the length of a single positron bunch was 12 mm at low current, rising to 13 mm at 1.5 mA and 14.8 mm at 3 mA. The electrons measured 12.2 mm at 16 MV with little current dependence. Both are longer than the expected low-current value of 10 mm (e{sup +}) and 10.5 mm (e{sup -}), derived from the energy spread and the measured synchrotron tune. We also determined the length for multibunch fills from measurements between 2 and 13 GHz of the bunch spectrum on a BPM button. After correcting for the frequency dependence of cable attenuation, we fitted the measured spectrum to that of a Gaussian bunch. At 3.8 MV, the positron measurement gave 13.2 mm at 1.5 mA/bunch in a full ring, shorter than the 15.6 mm found with the streak camera under these conditions, but we found 11.4 mm for the electrons at 16.7 MV and 1 mA/bunch, in good agreement with the 11 mm from multibunch streak measurements.

Physical Description

4 pages

Source

  • Presented atParticle Accelerator Conference (PAC 05), , 5/16/2005-5/20/2005

Language

Item Type

Identifier

Unique identifying numbers for this article in the Digital Library or other systems.

  • Report No.: SLAC-PUB-11230
  • Grant Number: AC02-76SF00515
  • Office of Scientific & Technical Information Report Number: 890447
  • Archival Resource Key: ark:/67531/metadc881914

Collections

This article is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

What responsibilities do I have when using this article?

When

Dates and time periods associated with this article.

Creation Date

  • June 10, 2005

Added to The UNT Digital Library

  • Sept. 21, 2016, 2:29 a.m.

Description Last Updated

  • Dec. 2, 2016, 8:45 p.m.

Usage Statistics

When was this article last used?

Congratulations! It looks like you are the first person to view this item online.

Interact With This Article

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Fisher, Alan S.; Novokhatski, A.; Turner, J.L.; Wienands, U.; Yocky, G.; /SLAC et al. Bunch-Length Measurements in PEP-II, article, June 10, 2005; [Menlo Park, California]. (digital.library.unt.edu/ark:/67531/metadc881914/: accessed August 16, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.