Status and performance of the CDF Run II silicon detector

PDF Version Also Available for Download.

Description

The CDF Run II silicon detector with its 8 layers of double- and single-sided silicon microstrip sensors and a total 722,432 readout channels is one of the largest silicon detector devices currently in use by a HEP experiment. We report our experience commissioning and operating this complex device during the first 4 years of Run II. As the luminosity delivered by the Tevatron increases, we have observed measurable effects of radiation damage in studies of charge collection and noise versus applied bias voltage at many different integrated luminosities. We discuss these studies and their impact on the expected lifetime of ... continued below

Physical Description

4 pages

Creation Information

Boveia, A. & /UC, Santa Barbara January 1, 2005.

Context

This article is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this article can be viewed below.

Who

People and organizations associated with either the creation of this article or its content.

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this article. Follow the links below to find similar items on the Digital Library.

Description

The CDF Run II silicon detector with its 8 layers of double- and single-sided silicon microstrip sensors and a total 722,432 readout channels is one of the largest silicon detector devices currently in use by a HEP experiment. We report our experience commissioning and operating this complex device during the first 4 years of Run II. As the luminosity delivered by the Tevatron increases, we have observed measurable effects of radiation damage in studies of charge collection and noise versus applied bias voltage at many different integrated luminosities. We discuss these studies and their impact on the expected lifetime of the detector.

Physical Description

4 pages

Source

  • Journal Name: PoS HEP2005:377,2006; Conference: Prepared for EPS International Europhysics Conference on High Energy Physics (HEP-EPS 2005), Lisbon, Portugal, 21-27 Jul 2005

Language

Item Type

Identifier

Unique identifying numbers for this article in the Digital Library or other systems.

  • Report No.: FERMILAB-CONF-05-604-E
  • Grant Number: AC02-76CH03000
  • Office of Scientific & Technical Information Report Number: 892392
  • Archival Resource Key: ark:/67531/metadc881875

Collections

This article is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this article?

When

Dates and time periods associated with this article.

Creation Date

  • January 1, 2005

Added to The UNT Digital Library

  • Sept. 21, 2016, 2:29 a.m.

Description Last Updated

  • Dec. 8, 2016, 11:15 p.m.

Usage Statistics

When was this article last used?

Congratulations! It looks like you are the first person to view this item online.

Interact With This Article

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Boveia, A. & /UC, Santa Barbara. Status and performance of the CDF Run II silicon detector, article, January 1, 2005; Batavia, Illinois. (digital.library.unt.edu/ark:/67531/metadc881875/: accessed December 14, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.