This report documents an investigation into the tritium inventory expected in the ARIES-AT fusion reactor. ARIES-AT features silicon carbide fibers in a silicon carbide matrix as its primary construction. It uses the same fusion power core as the previous ARIES-RS. Based on experimental results of several researchers, consideration was given to swelling, sputtering, film coatings, erosion, and implantation. Estimates were made of tritium inventory using the TMAP4 code. About 700 g of tritium may be expected in the machines, two thirds of which would reside in the first wall. Under assumed accident conditions that involve firs wall temperatures up to ... continued below

Creation Information

Longhurst, Glen Reed February 1, 2001.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

This report documents an investigation into the tritium inventory expected in the ARIES-AT fusion reactor. ARIES-AT features silicon carbide fibers in a silicon carbide matrix as its primary construction. It uses the same fusion power core as the previous ARIES-RS. Based on experimental results of several researchers, consideration was given to swelling, sputtering, film coatings, erosion, and implantation. Estimates were made of tritium inventory using the TMAP4 code. About 700 g of tritium may be expected in the machines, two thirds of which would reside in the first wall. Under assumed accident conditions that involve firs wall temperatures up to 1000°C, evolution of retained tritium may be expected to vary from 0.8 to nearly 40 percent depending on the temperature of the first wall.

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Report No.: INEEL/EXT-01-00306
  • Grant Number: DE-AC07-99ID-13727
  • DOI: 10.2172/911447 | External Link
  • Office of Scientific & Technical Information Report Number: 911447
  • Archival Resource Key: ark:/67531/metadc880314

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • February 1, 2001

Added to The UNT Digital Library

  • Sept. 22, 2016, 2:13 a.m.

Description Last Updated

  • Dec. 7, 2016, 11:21 p.m.

Usage Statistics

When was this report last used?

Congratulations! It looks like you are the first person to view this item online.

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Longhurst, Glen Reed. Tritium Inventory in Aries-AT, report, February 1, 2001; [Idaho Falls, Idaho]. (digital.library.unt.edu/ark:/67531/metadc880314/: accessed August 21, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.