This project evaluates what $/kW subsidy on microturbines (MT's) makes them economically competitive with natural gas internal combustion engines (ICE's). The Distributed Energy Resources Customer Adoption Model (DER-CAM) is used to determine least cost solutions, including distributed generation (DG) investment and operation, to sites' energy demands. The first site considered is a hospital in New York City. The small hospital (90 beds) has a peak electric load (including cooling) of 1200 kW, with heat loads comparable to electric loads. Consolidated Edison electricity and natural gas tariffs for 2003 are used. A 60% minimum DG system efficiency is imposed on DG ... continued below

Creation Information

Firestone, Ryan & Marnay, Chris December 31, 2005.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

This project evaluates what $/kW subsidy on microturbines (MT's) makes them economically competitive with natural gas internal combustion engines (ICE's). The Distributed Energy Resources Customer Adoption Model (DER-CAM) is used to determine least cost solutions, including distributed generation (DG) investment and operation, to sites' energy demands. The first site considered is a hospital in New York City. The small hospital (90 beds) has a peak electric load (including cooling) of 1200 kW, with heat loads comparable to electric loads. Consolidated Edison electricity and natural gas tariffs for 2003 are used. A 60% minimum DG system efficiency is imposed on DG operation to avoid the standby tariff, which is less amenable to DG than the parent tariff. The second site considered is the Naval Base Ventura County commissary in Southern California. The commissary has 13,000 m{sup 2} of floor space and contains a large retail store, supermarket, food court, and other small businesses. The site peak electric load (including cooling) is 1050 kW. Electricity and natural gas supply are from direct access contracts, and delivery service is provided by Southern California Edison and Southern California Gas, respectively. 2003 supply and delivery rates are used.

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Report No.: LBNL--57985
  • Grant Number: DE-AC02-05CH11231
  • DOI: 10.2172/878537 | External Link
  • Office of Scientific & Technical Information Report Number: 878537
  • Archival Resource Key: ark:/67531/metadc878502

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • December 31, 2005

Added to The UNT Digital Library

  • Sept. 21, 2016, 2:29 a.m.

Description Last Updated

  • Sept. 29, 2016, 3:19 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 1

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Firestone, Ryan & Marnay, Chris. Microturbine Economic Competitiveness: A Study of Two PotentialAdopters, report, December 31, 2005; Berkeley, California. (digital.library.unt.edu/ark:/67531/metadc878502/: accessed October 19, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.