Waste in large waste boxes can generate volatile organic compounds (VOCs) and hydrogen. These waste boxes may or may not have flow paths out of them (although it is believed that most do). These boxes will be retrieved, sampled, and then coated with polyurea. After coating, filters will be installed in the box to keep the concentration of VOCs and hydrogen acceptably low. The MDSA requires that a vent path must be protected during application of the polyurea coating. If the box has been sampled then it is vented and the vent path must be protected. This report provides a ...
continued below
Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.
Descriptive information to help identify this report.
Follow the links below to find similar items on the Digital Library.
Description
Waste in large waste boxes can generate volatile organic compounds (VOCs) and hydrogen. These waste boxes may or may not have flow paths out of them (although it is believed that most do). These boxes will be retrieved, sampled, and then coated with polyurea. After coating, filters will be installed in the box to keep the concentration of VOCs and hydrogen acceptably low. The MDSA requires that a vent path must be protected during application of the polyurea coating. If the box has been sampled then it is vented and the vent path must be protected. This report provides a model in which the user inputs the free volume of the waste box, sample concentration (ppm of total VOC or volume fraction hydrogen) along with the number of filters to be placed into the waste box lid. Using this information, the model provides an estimate of concentration vs. time or the number of filters needed to reduce the concentration by a specified fraction. If the equations from this report are placed into spreadsheets which are then used to demonstrate TSR compliance, the spreadsheets must come under the Software QA Plan for such documents. Chapters 2 and 3 present the theory. Chapter 4 presents the method with examples of its use found in Chapter 5. Chapter 6 provides the basis far the use of 1,000 ppm as the concentration below which the method is valid under any condition.
This report is part of the following collection of related materials.
Office of Scientific & Technical Information Technical Reports
Reports, articles and other documents harvested from the Office of Scientific and Technical Information.
Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.
MARUSICH, R.M.METHODOLOGY FOR THE NUMBER OF FILTERS NEEDED IN A WASTE BOX,
report,
May 17, 2007;
Richland, Washington.
(digital.library.unt.edu/ark:/67531/metadc878266/: