A mass gaging technique is being investigated in which the detector alternately views radiations transmitted through the test specimen and through a calibrated step wedge. Thulium-170 was used in initial investigations; however, sources of higher and lower energies are to be examined. Variations of balancing systmas are discussed and results of tests using NaI(Tl) and CsI(Tl) crystals with non-commutating systems are tabulated. Commutating system's operation was tested at a chopping frequency of 10 cps. Much smoother servo operation was noted than was demonstrated by the non-commutating system. A circuit diagram of the commutating system is included. (J.R.D.)

Physical Description

Pages: 20

Creation Information

Burgwald, G.M. October 1, 1959.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

A mass gaging technique is being investigated in which the detector alternately views radiations transmitted through the test specimen and through a calibrated step wedge. Thulium-170 was used in initial investigations; however, sources of higher and lower energies are to be examined. Variations of balancing systmas are discussed and results of tests using NaI(Tl) and CsI(Tl) crystals with non-commutating systems are tabulated. Commutating system's operation was tested at a chopping frequency of 10 cps. Much smoother servo operation was noted than was demonstrated by the non-commutating system. A circuit diagram of the commutating system is included. (J.R.D.)

Physical Description

Pages: 20

Notes

NTIS

Source

  • Other Information: Orig. Receipt Date: 31-DEC-60

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Report No.: ARF-1152-3
  • Grant Number: AT(11-1)-745
  • DOI: 10.2172/4201842 | External Link
  • Office of Scientific & Technical Information Report Number: 4201842
  • Archival Resource Key: ark:/67531/metadc878254

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • October 1, 1959

Added to The UNT Digital Library

  • Sept. 21, 2016, 2:29 a.m.

Usage Statistics

When was this report last used?

Congratulations! It looks like you are the first person to view this item online.

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Burgwald, G.M. AN IMPROVED NUCLEAR DENSITY GAUGE. Quarterly Report No. 1 Covering the Period from June 1 to September 1, 1959, report, October 1, 1959; United States. (digital.library.unt.edu/ark:/67531/metadc878254/: accessed August 22, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.