New Results with the superconducting ECR ion source VENUS

PDF Version Also Available for Download.

Description

During the last year, the VENUS ECR ion source was commissioned at 18 GHz and preparations for 28 GHz operation, which is set to begin early in 2004, are now underway. The goal of the VENUS ECR ion source project as the RIA R&D injector is the production of 240emA of U30+, a high current medium charge state beam. On the other hand, as an injector ion source for the 88-Inch Cyclotron the design objective is the production of 5emA of U48+, a low current, very high charge state beam. During the commissioning phase with 18 GHz, tests with various ... continued below

Creation Information

Lyneis, C.M.; Leitner, D.; Abbott, S.R.; Dwinell, R.D.; Leitner,M.; Silver, C.S. et al. May 13, 2004.

Context

This article is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this article can be viewed below.

Who

People and organizations associated with either the creation of this article or its content.

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this article. Follow the links below to find similar items on the Digital Library.

Description

During the last year, the VENUS ECR ion source was commissioned at 18 GHz and preparations for 28 GHz operation, which is set to begin early in 2004, are now underway. The goal of the VENUS ECR ion source project as the RIA R&D injector is the production of 240emA of U30+, a high current medium charge state beam. On the other hand, as an injector ion source for the 88-Inch Cyclotron the design objective is the production of 5emA of U48+, a low current, very high charge state beam. During the commissioning phase with 18 GHz, tests with various gases and recently metals have been performed with up to 2000 W RF power and the performance is very promising. For example, 1100 e mu A of O6+,180 e mu A of Ar12+, 150 emA of Xe20+ and 100 emA of Bi24+ were produced in the early commissioning phase, ranking VENUS among the currently highest performance 18 GHz ECR ion sources. The emittance of the beams produced at 18 GHz was measured with a two axis emittance scanner. In FY04 a 10 kW, 28 GHz gyrotron system will be added, which will enable VENUS to reach full performance. The performance of the VENUS ion source, low energy beam transport (LEBT) and its closed loop cryogenic system are described in the paper. Recently, a new high temperature axial oven has been installed in the source and the first results on metal beams such as bismuth are given. The design of the 28 GHz, 10 kW gyrotron system is also be described. During the last year, the VENUS ECR ion source was commissioned at 18 GHz and preparations for 28 GHz operation, which is set to begin early in 2004, are now underway. The goal of the VENUS ECR+, a high current medium charge state beam. On the other hand, as an injector ion source for the 88-Inch Cyclotron the design objective is the production of 5 emA of U48+, a low current, very high charge state beam. During the commissioning phase with 18 GHz, tests with various gases and recently metals have been performed with up to 2000 W RF power and the performance is very promising. For example, 1100 e mu A of O6+, 180 e muA of Ar12+, 150 emA of Xe20+ and 100 emA of Bi24+ were produced in the early commissioning phase, ranking VENUS among the currently highest performance 18 GHz ECR ion sources. The emittance of the beams produced at 18 GHz was measured with a two axis emittance scanner. In FY04 a 10kW, 28 GHz gyrotron system will be added, which will enable VENUS to reach full performance. The performance of the VENUS ion source, low energy beam transport (LEBT) and its closed loop cryogenic system are described in the paper. Recently, a new high temperature axial oven has been installed in the source and the first results on metal beams such as bismuth are given. The design of the 28 GHz, 10 kW gyrotron system is also be described.

Source

  • 10th International Conference on Ion Sources,Dubna, Russia, 8-13 September 2003

Language

Item Type

Identifier

Unique identifying numbers for this article in the Digital Library or other systems.

  • Report No.: LBNL--57003
  • Grant Number: DE-AC02-05CH11231
  • Office of Scientific & Technical Information Report Number: 885231
  • Archival Resource Key: ark:/67531/metadc876088

Collections

This article is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

What responsibilities do I have when using this article?

When

Dates and time periods associated with this article.

Creation Date

  • May 13, 2004

Added to The UNT Digital Library

  • Sept. 21, 2016, 2:29 a.m.

Description Last Updated

  • Sept. 29, 2016, 3:22 p.m.

Usage Statistics

When was this article last used?

Yesterday: 1
Past 30 days: 3
Total Uses: 4

Interact With This Article

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Lyneis, C.M.; Leitner, D.; Abbott, S.R.; Dwinell, R.D.; Leitner,M.; Silver, C.S. et al. New Results with the superconducting ECR ion source VENUS, article, May 13, 2004; Berkeley, California. (digital.library.unt.edu/ark:/67531/metadc876088/: accessed September 22, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.