In this report we describe the new two-phase flow facility that has been constructed at Brown University. Included is the design philosophy that led us to select a blow-down, Freon tunnel as the means of studying the flow of a pure substance undergoing liquid-vapor phase changes. Each component is discussed from the initial design considerations, through sizing calculations, to actual system specifications. Special emphasis is placed on the instrumentation and automatic data acquisition and processing system. Finally a sampling of results obtained so far is presented. Section 1 gives the reasons for the construction of the facility and lists some ... continued below

Creation Information

Maeder, P.F.; Kestin, J.; Dickinson, D.A.; DiPippo, R. & Olia, H. May 1, 1982.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Publishers

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

In this report we describe the new two-phase flow facility that has been constructed at Brown University. Included is the design philosophy that led us to select a blow-down, Freon tunnel as the means of studying the flow of a pure substance undergoing liquid-vapor phase changes. Each component is discussed from the initial design considerations, through sizing calculations, to actual system specifications. Special emphasis is placed on the instrumentation and automatic data acquisition and processing system. Finally a sampling of results obtained so far is presented. Section 1 gives the reasons for the construction of the facility and lists some of the uses and objectives of its operation. The reader can gain a good overview of the facility from Section 2 without a great deal of detail. In Section 3 we present the rationale for the particular design choices that were made and give details about the selection and sizing of all major components except the instrumentation. The latter subject is treated in Section 4 where we discuss the temperature and pressure probes, mass flow rate measurement, and other instrumentation. Section 5 is devoted to the test section proper where all the two-phase flow measurements and observations take place. The electronic data acquisition and facility control system is the subject of Section 6. Results on two-phase friction factors and flow pattern observations in a horizontal pipe are given in Section 7 along with the ranges of flow that have been covered so far. In capsule summary, the two-phase flow test facility is operational and has demonstrated a wide range of flow conditions from purely liquid to purely vapor through a variety of two-phase situations. Only horizontal flows have been studied so far, but the test section has been designed to operate in inclined positions up to fully vertical. The instrumentation performs very well as does the fully automatic control system. We believe the test facility is capable of yielding highly reliable and accurate data on two-phase flows which will be of great value in practice and in validating the various theories that have been put forth to describe this phenomenon.

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Report No.: LA-UR-82-1838
  • Grant Number: DE-AC02-79ET27225
  • DOI: 10.2172/893472 | External Link
  • Office of Scientific & Technical Information Report Number: 893472
  • Archival Resource Key: ark:/67531/metadc875659

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • May 1, 1982

Added to The UNT Digital Library

  • Sept. 21, 2016, 2:29 a.m.

Description Last Updated

  • Dec. 9, 2016, 7:55 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 1
Total Uses: 5

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

International Image Interoperability Framework

IIF Logo

We support the IIIF Presentation API

Maeder, P.F.; Kestin, J.; Dickinson, D.A.; DiPippo, R. & Olia, H. Design and operation of a two-phase flow research facility, report, May 1, 1982; Los Alamos, New Mexico. (digital.library.unt.edu/ark:/67531/metadc875659/: accessed November 14, 2018), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.