MAGNETIC RECORDER FOR NUCLEAR PULSE APPLICATION. Period covered: December 6, 1959 to February 5, 1960

PDF Version Also Available for Download.

Description

An evaluation of a modulator flux sensitive playback head to be used with an analog magnetic recorder for nuclear pulse information storage was made. The modulator head was found unsultable. A pulse stretching unit was constructed which takes pulses from a standard linear pulse amplifier and provides an output signal suitable for driving a recording head. (For preceding period see ARF-1151- 3.) (C.J.G.)

Physical Description

8 p.

Creation Information

Burgwald, G.M. & Norton, R.M. February 24, 1960.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by the UNT Libraries Government Documents Department to the UNT Digital Library, a digital repository hosted by the UNT Libraries. It has been viewed 39 times. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

An evaluation of a modulator flux sensitive playback head to be used with an analog magnetic recorder for nuclear pulse information storage was made. The modulator head was found unsultable. A pulse stretching unit was constructed which takes pulses from a standard linear pulse amplifier and provides an output signal suitable for driving a recording head. (For preceding period see ARF-1151- 3.) (C.J.G.)

Physical Description

8 p.

Notes

NTIS

Other Information: Orig. Receipt Date: 31-DEC-60

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • February 24, 1960

Added to The UNT Digital Library

  • Sept. 16, 2016, 12:32 a.m.

Description Last Updated

  • Nov. 24, 2024, 11:50 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 39

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

International Image Interoperability Framework

IIF Logo

We support the IIIF Presentation API

Burgwald, G.M. & Norton, R.M. MAGNETIC RECORDER FOR NUCLEAR PULSE APPLICATION. Period covered: December 6, 1959 to February 5, 1960, report, February 24, 1960; Chicago, Illinois. (https://digital.library.unt.edu/ark:/67531/metadc871458/: accessed May 15, 2025), University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu; crediting UNT Libraries Government Documents Department.

Back to Top of Screen