Tensile properties of pyrolytic graphite were measured parallel to the basal planes from room temperature to 5000 deg F. The gage section of the test specimen was 0.06 by 0.10 in. in cross section and3/4-in. long. The specimens were heated in a helium atmosphere by an external graphite heater and were tested at a strain rate of approx 2 x 10/sup -//sup 4/ in./in./sec. Tensile strengths at room temperatare varied from 6,000 to 19,000 psi with elongations of less thsn 1%. At 3000 deg F the strength and elongation were approximately the same as at room temperature. At 4000 deg …
continued below
Publisher Info:
California Inst. of Tech., Pasadena. Jet Propulsion Lab.
Place of Publication:
Pasadena, California
Provided By
UNT Libraries Government Documents Department
Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.
Descriptive information to help identify this report.
Follow the links below to find similar items on the Digital Library.
Description
Tensile properties of pyrolytic graphite were measured parallel to the basal planes from room temperature to 5000 deg F. The gage section of the test specimen was 0.06 by 0.10 in. in cross section and3/4-in. long. The specimens were heated in a helium atmosphere by an external graphite heater and were tested at a strain rate of approx 2 x 10/sup -//sup 4/ in./in./sec. Tensile strengths at room temperatare varied from 6,000 to 19,000 psi with elongations of less thsn 1%. At 3000 deg F the strength and elongation were approximately the same as at room temperature. At 4000 deg F there was a very slight increase in the strength and elongation. At 4500 deg F tensile strengths to 35,000 psi and elongations up to 3%, and at 5000"F tensile strengths of 64,000 psi and elongations greater than 70% were measured. At 4500 deg F and above load-deformation curves were recorded. Microstructure and x-ray diffraction patterns showed that marked structural changes accompsny deformation at 5000 deg F. Large changes in room-temperature dimensions, parallel and perpendicular to the basal planes, were measured after heating, with no load, to temperatures in this same range. (auth)
This report is part of the following collection of related materials.
Office of Scientific & Technical Information Technical Reports
Reports, articles and other documents harvested from the Office of Scientific and Technical Information.
Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.
Kotlensky, W. V. & Martens, H. E.Tensile Properties of Pyrolytic Graphite to 5000 F,