Analysis Of Tank 38H (HTF-38-14-6, 7) And Tank 43H (HTF-43-14-8, 9) Samples For Support Of The Enrichment Control And Corrosion Control Programs

PDF Version Also Available for Download.

Description

SRNL performed analysis on Tanks 38H and 43H surface and subsurface supernate samples to support ECP and CCP. The U-235 mass divided by the total U mass ranged from 0.0059 to 0.0060. Uranium concentration ranged from 53.1 mg/L in the Tank 43H surface sample to the 85.1 mg/L in the Tank 38H subsurface sample. The U-235/U and uranium concentration are in line with the prior 2H-Evaporator System ECP samples.

Physical Description

13 p.

Creation Information

Martino, C. J. February 27, 2014.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Publisher

  • Savannah River Site (S.C.)
    Publisher Info: Savannah River Site (SRS), Aiken, SC (United States)
    Place of Publication: Aiken, South Carolina

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

SRNL performed analysis on Tanks 38H and 43H surface and subsurface supernate samples to support ECP and CCP. The U-235 mass divided by the total U mass ranged from 0.0059 to 0.0060. Uranium concentration ranged from 53.1 mg/L in the Tank 43H surface sample to the 85.1 mg/L in the Tank 38H subsurface sample. The U-235/U and uranium concentration are in line with the prior 2H-Evaporator System ECP samples.

Physical Description

13 p.

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Report No.: SRNL-STI--2014-00081
  • Grant Number: DE-AC09-08SR22470
  • DOI: 10.2172/1122184 | External Link
  • Office of Scientific & Technical Information Report Number: 1122184
  • Archival Resource Key: ark:/67531/metadc870358

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • February 27, 2014

Added to The UNT Digital Library

  • Sept. 16, 2016, 12:32 a.m.

Description Last Updated

  • Dec. 6, 2016, 6:16 p.m.

Usage Statistics

When was this report last used?

Congratulations! It looks like you are the first person to view this item online.

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Martino, C. J. Analysis Of Tank 38H (HTF-38-14-6, 7) And Tank 43H (HTF-43-14-8, 9) Samples For Support Of The Enrichment Control And Corrosion Control Programs, report, February 27, 2014; Aiken, South Carolina. (digital.library.unt.edu/ark:/67531/metadc870358/: accessed September 24, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.