Xenon Transient. Core 1, Seed 1. Test Results T-612081. Section 1

PDF Version Also Available for Download.

Description

A test was conducted to determine if there is sufficient excess reactivity after 5532.3 EFPH for Core 1 Seed 1 to override a Xe transient, and to obtain data for rod worth calculations. The core did not contain enough reactivity to override Xe poisoning during the first 35 hrs after shutdown. As a result, the point at which peak Xe occurred could not be determined. Data on rod worth are included. (J.R.D.)

Physical Description

18 p.

Creation Information

Creator: Unknown. April 1, 1961.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Creator

  • We've been unable to identify the creator(s) of this report.

Publisher

  • Duquesne Light Company
    Publisher Info: Duquesne Light Co., Shippingport, Penna.
    Place of Publication: Shippingport, Pennsylvania

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

A test was conducted to determine if there is sufficient excess reactivity after 5532.3 EFPH for Core 1 Seed 1 to override a Xe transient, and to obtain data for rod worth calculations. The core did not contain enough reactivity to override Xe poisoning during the first 35 hrs after shutdown. As a result, the point at which peak Xe occurred could not be determined. Data on rod worth are included. (J.R.D.)

Physical Description

18 p.

Source

  • Other Information: Orig. Receipt Date: 31-DEC-61

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Report No.: DLCS-1560106
  • Grant Number: None
  • DOI: 10.2172/4091890 | External Link
  • Office of Scientific & Technical Information Report Number: 4091890
  • Archival Resource Key: ark:/67531/metadc869336

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • April 1, 1961

Added to The UNT Digital Library

  • Sept. 16, 2016, 12:32 a.m.

Description Last Updated

  • Oct. 12, 2017, 2:36 p.m.

Usage Statistics

When was this report last used?

Congratulations! It looks like you are the first person to view this item online.

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Xenon Transient. Core 1, Seed 1. Test Results T-612081. Section 1, report, April 1, 1961; Shippingport, Pennsylvania. (digital.library.unt.edu/ark:/67531/metadc869336/: accessed January 16, 2018), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.