The Charpy V-notch (C/sub v/) upper-shelf energy is usually defined as that temperature range in which the surface of the C/sub v/ specimen exhibits an appearance indicative of a 100 percent ductile fracture. In an attempt to avoid the need for interpretation, the selection of the C/sub v/ upper-shelf energy is based on the results from an instrumented impact test which provides a permanent record of the load-deflection history of a C/sub v/ specimen during the testing sequence. In the brittle-ductile transition temperature regime, a precipitous drop in the load trace occurs. The amount of the drop decreases at higher ...
continued below
Publisher Info:
Oak Ridge National Lab., Tenn. (USA)
Place of Publication:
Tennessee
Provided By
UNT Libraries Government Documents Department
Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.
Descriptive information to help identify this report.
Follow the links below to find similar items on the Digital Library.
Description
The Charpy V-notch (C/sub v/) upper-shelf energy is usually defined as that temperature range in which the surface of the C/sub v/ specimen exhibits an appearance indicative of a 100 percent ductile fracture. In an attempt to avoid the need for interpretation, the selection of the C/sub v/ upper-shelf energy is based on the results from an instrumented impact test which provides a permanent record of the load-deflection history of a C/sub v/ specimen during the testing sequence. In the brittle-ductile transition temperature regime, a precipitous drop in the load trace occurs. The amount of the drop decreases at higher temperatures until it is zero, and the zero-drop-in-load temperature is identical to the onset of the C/sub v/ upper shelf. This relationship between the drop in load and energy in an instrumented impact test provides incontestable assurance that the C/sub v/ upper shelf has been obtained. This relationship between drop in load and temperature permits a prediction of the onset of the upper-shelf temperature with as few as two instrumented impact tests. It is also shown that nil-ductility temperature (NDT) (determined by the drop-weight test) is released to the C/sub v/ upper shelf. For the SA-508 Class 2 and SA-533 Grade B Class 1 steels employed in the fabrication of pressure vessels for light-water reactors, C/sub v/ testing at NDT + 180$sup 0$F (100$sup 0$C) will provide upper-shelf energy values. (DLC)
This report is part of the following collection of related materials.
Office of Scientific & Technical Information Technical Reports
Reports, articles and other documents harvested from the Office of Scientific and Technical Information.
Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.
Canonico, D.A.; Stelzman, W.J.; Berggren, R.G. & Nanstad, R.K.Use of instrumented charpy tests to determine onset of upper-shelf energy,
report,
November 1, 1975;
Tennessee.
(digital.library.unt.edu/ark:/67531/metadc866355/:
accessed February 23, 2019),
University of North Texas Libraries, Digital Library, digital.library.unt.edu;
crediting UNT Libraries Government Documents Department.