4X6" Rotary Bayonet LN2 Test Fill

PDF Version Also Available for Download.

Description

This engineering note describes a test fill of the 4-inch x 6-inch rotary bayonet test fixture with LN{sub 2}. This test verifies the operation of valves on the fixture, and checks for proper construction/insulation. Further cold testing is imminent (with rotation and moment loading of the bayonet) after proper construction is verified and the test fixture is accepted. While this test fixture is a pressure vessel (4-inch), it does not require special safety treatment because it is under 6-inch in diameter. Flow capacity calculations were done to insure that the relief valve chosen would be capable of handling fire/loss of ... continued below

Physical Description

33 pages

Creation Information

Fitzpatrick, J.B. August 2, 1988.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Author

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

This engineering note describes a test fill of the 4-inch x 6-inch rotary bayonet test fixture with LN{sub 2}. This test verifies the operation of valves on the fixture, and checks for proper construction/insulation. Further cold testing is imminent (with rotation and moment loading of the bayonet) after proper construction is verified and the test fixture is accepted. While this test fixture is a pressure vessel (4-inch), it does not require special safety treatment because it is under 6-inch in diameter. Flow capacity calculations were done to insure that the relief valve chosen would be capable of handling fire/loss of vacuum conditions. The D-Zero Safety Committee Chairman was notified of this testing.

Physical Description

33 pages

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Report No.: FERMILAB-D0-EN-171
  • Grant Number: AC02-07CH11359
  • DOI: 10.2172/1031181 | External Link
  • Office of Scientific & Technical Information Report Number: 1031181
  • Archival Resource Key: ark:/67531/metadc845109

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • August 2, 1988

Added to The UNT Digital Library

  • May 19, 2016, 3:16 p.m.

Description Last Updated

  • Aug. 30, 2016, 3:45 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 9

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

International Image Interoperability Framework

IIF Logo

We support the IIIF Presentation API

Fitzpatrick, J.B. 4X6" Rotary Bayonet LN2 Test Fill, report, August 2, 1988; Batavia, Illinois. (digital.library.unt.edu/ark:/67531/metadc845109/: accessed July 17, 2018), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.