SAFETY ANALYSIS REPORT FOR PACKAGING, MODEL 9977, ADDENDUM 3, JUSTIFICATION FOR SMALL GRAM QUANTITY CONTENTS Page: 29 of 120
This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided to UNT Digital Library by the UNT Libraries Government Documents Department.
Extracted Text
The following text was automatically extracted from the image on this page using optical character recognition software:
Justification for Small Gram Quantity Contents
CHAPTER 3 -- THERMAL EVALUATION
The decay-heat rates for the SGQ Contents are limited to the 19-Watt package thermal limit for
the 9977. Therefore, the package thermal performance documented in the 9977 SARP Revision
2 is equally valid for all three shielded container configurations with the SGQ Content Envelope.
The MNOP is reevaluated for the SGQ Contents and SGQ Containers.
3.1 DESCRIPTION OF THERMAL DESIGN
Thermal performance of the package under NCT and HAC was verified by testing and quantified by
analysis. The NCT and HAC test results are documented in SARP Appendices 3.1 and 3.2. The NCT and
HAC analyses are documented in SARP Appendices 3.3, 3.4, and in Addendum Appendix A.3.1 and
summarized in SARP Table 3.2 and Addendum Table A.3.1. The calculated temperatures compare closely
with the measured temperatures and are bounding for all SGQ Content envelopes and configurations
identified in Section 1.2.2.
Table A.3.1 - Maximum NCT Temperatures - Engineered Container and Shielded Container Configurations
Insolation Heat Rate CV Wall O-Rings Payload Payload Drum Wall
Model (Max) (Average) Actual Limit
(Watts) ( F) ( F) ( F) ( F) ( F) ( F)
Yes 19 314 284 349 314 na na
SGQ-SC1 Yes 6 236 227 247 236 na na
(Lead Shielding) No 19 213 180 255 nc 105 122
No 11.5 172 150 199 nc 103 122
Yes 19 297 282 312 298 na na
SGQ-SC2
(H QESCd Yes 3 228 228 nc 226 na na
(HDPE Shielding)
No 19 202 181 249 218 105 122
SGQ-SC3 Yes 19 307 276 351 306 na na
(Tungsten Shielding) No 19 215 175 268 nc 105 122
SGQ-EC1 Yes 19 a 309 283 1120 nc nc nc
(Engineered Container) Yes 19 305 284 349 nc nc nc
na not applicable
nc not calculated
a Content modeled as a "point source" %-inch diameter x 1-inch long (per baseline model, SARP Section 3.3.1.1.4)
b Content modeled as a "finite source" 2-inches diameter x 6.75-inches long
Addendum Figures A.3.1, A.3.2, and A.3.3 show the material representation of the SGQ-SC1, SGQ-SC2,
and SGQ-SC3 configurations, respectively. Addendum Figure A.3.4 is a material representation of the
SGQ-EC1 configuration.23
S-SARA-G-00006, Revision 5
Upcoming Pages
Here’s what’s next.
Search Inside
This report can be searched. Note: Results may vary based on the legibility of text within the document.
Tools / Downloads
Get a copy of this page or view the extracted text.
Citing and Sharing
Basic information for referencing this web page. We also provide extended guidance on usage rights, references, copying or embedding.
Reference the current page of this Report.
Abramczyk, G. SAFETY ANALYSIS REPORT FOR PACKAGING, MODEL 9977, ADDENDUM 3, JUSTIFICATION FOR SMALL GRAM QUANTITY CONTENTS, report, October 31, 2011; United States. (https://digital.library.unt.edu/ark:/67531/metadc844292/m1/29/: accessed April 23, 2024), University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu; crediting UNT Libraries Government Documents Department.