The purpose of this study is to determine if a hazardous condition is created by accidental closing of the coolant loop isolation valves�while the reactor is operating.
Publisher Info:
CHO (Chicago Operations Office, Argonne, IL (United States))
Place of Publication:
Argonne, Illinois
Provided By
UNT Libraries Government Documents Department
Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.
Descriptive information to help identify this report.
Follow the links below to find similar items on the Digital Library.
Description
The purpose of this study is to determine if a hazardous condition is created by accidental closing of the coolant loop isolation valves�while the reactor is operating.
This report is part of the following collection of related materials.
Office of Scientific & Technical Information Technical Reports
Reports, articles and other documents harvested from the Office of Scientific and Technical Information.
Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.
DeAgazio, A.Inadvertent Operation Coolant Loop Isolation Valves Hazards Analysis. Study No. IV - 320,
report,
February 24, 1961;
Argonne, Illinois.
(https://digital.library.unt.edu/ark:/67531/metadc834878/: