Description

Here is a review of the current way we handle source photons in Implicit Monte Carlo (IMC). A source photon is created with a randomly sampled position x{sub p} in the zone, a direction {Omega}{sub p}, a frequency v{sub p} sampled from the appropriate distribution, and a time t{sub p} uniformly sampled from [t{sup n}, t{sup n+1}]. The source photons each have an energy E{sub p}. The sum of E{sub p} over all of the photons equals the energy of the source for that time step. In the case of thermal emission in a zone with Volume V, they would ... continued below

Physical Description

PDF-file: 15 pages; size: 0.2 Mbytes

Creation Information

Gentile, N A January 24, 2011.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. It has been viewed 23 times , with 11 in the last month . More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Author

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

Here is a review of the current way we handle source photons in Implicit Monte Carlo (IMC). A source photon is created with a randomly sampled position x{sub p} in the zone, a direction {Omega}{sub p}, a frequency v{sub p} sampled from the appropriate distribution, and a time t{sub p} uniformly sampled from [t{sup n}, t{sup n+1}]. The source photons each have an energy E{sub p}. The sum of E{sub p} over all of the photons equals the energy of the source for that time step. In the case of thermal emission in a zone with Volume V, they would have {Sigma}{sub p=1}{sup N} E{sub p} = {sigma} {sub p}acT{sup 4}V{Delta}t, where N is the number of thermal source photons for that time step, and {sigma}{sub p} is the Planck mean opacity. Census photons do not differ from source photons in any way, except that they all start the time step with t{sub p} = t{sup n}. Then they advance each photon until it reaches the end of the time step. When they are done with all of the photons, they update the matter temperature using the difference between the emitted and absorbed energy, and proceed to the next time step.

Physical Description

PDF-file: 15 pages; size: 0.2 Mbytes

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Report No.: LLNL-TR-469237
  • Grant Number: W-7405-ENG-48
  • DOI: 10.2172/1018761 | External Link
  • Office of Scientific & Technical Information Report Number: 1018761
  • Archival Resource Key: ark:/67531/metadc831143

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • January 24, 2011

Added to The UNT Digital Library

  • May 19, 2016, 3:16 p.m.

Description Last Updated

  • Dec. 9, 2016, 8:43 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 11
Total Uses: 23

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

International Image Interoperability Framework

IIF Logo

We support the IIIF Presentation API

Gentile, N A. Smoothed Emission for IMC, report, January 24, 2011; Livermore, California. (digital.library.unt.edu/ark:/67531/metadc831143/: accessed December 14, 2018), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.