Any detectable leakage emanating from the argon storage dewar is undesirable; not only from a safety standpoint (eg, cryogenic burns, asphyxiation, etc.), but also small amounts of air back diffusing through leaks can render the argon unsuitable for the future physics experiments to take place within the cryostats. Whereas leakage through some of the control and manually operated valves on the dewar does not necessarily infroduce any of the above hazards directly, it could be high enough to be an economical, and perhaps an operational nuisance. Contained in the following is a compilation of the final leakage rates associated with ... continued below

Physical Description

10 pages

Creation Information

Dixon, K. May 30, 1990.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. It has been viewed 22 times . More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Author

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

Any detectable leakage emanating from the argon storage dewar is undesirable; not only from a safety standpoint (eg, cryogenic burns, asphyxiation, etc.), but also small amounts of air back diffusing through leaks can render the argon unsuitable for the future physics experiments to take place within the cryostats. Whereas leakage through some of the control and manually operated valves on the dewar does not necessarily infroduce any of the above hazards directly, it could be high enough to be an economical, and perhaps an operational nuisance. Contained in the following is a compilation of the final leakage rates associated with the dewar during the period of January through May of 1990 and the raw data from which they were derived from. Also contained is a calculation of the total maximum allowable leakage rate int%ut of the dewar. The general strategy employed while leak checking the dewar was to eliminate all leaks found which could be relatively easily stopped and to reduce the more difficult ones to an acceptable level. Leakage past the seats/plugs of control and main relief valves in addition to leakage past the ball seals in the diverter valve fell into the latter category. Helium mass spectrometer leak detector (HMSLD), rate of rise (ROR) method, and throughput calculations based on effective pumping speeds were the means used to determine leakage rates. Usually the HMSLD method was used to detect the numerous smaller leaks (1 OE-S to 1 OE-1 0 std eels) which were eventually stopped by thread tightening, gasket replacement. redesign, etc. The ROR method helped measure the leakage past valve plugs and establish outgassing rates for volumes deemed as being tight; ie, no detectable leakage using the HMSLD. The throughput calculation was used only to determine the relatively large leak past the plug/seat of the vaporizer valve. A sample calculation of each leakage rate determining method is attached to this note. All leakage rates are given for helium gas at one atm differential.

Physical Description

10 pages

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Report No.: FERMILAB-D0-EN-255
  • Grant Number: AC02-07CH11359
  • DOI: 10.2172/1031840 | External Link
  • Office of Scientific & Technical Information Report Number: 1031840
  • Archival Resource Key: ark:/67531/metadc830059

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • May 30, 1990

Added to The UNT Digital Library

  • May 19, 2016, 3:16 p.m.

Description Last Updated

  • Aug. 30, 2016, 4:28 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 22

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

International Image Interoperability Framework

IIF Logo

We support the IIIF Presentation API

Dixon, K. Initial DAB Argon Storage Dewar Leakage, report, May 30, 1990; Batavia, Illinois. (digital.library.unt.edu/ark:/67531/metadc830059/: accessed November 14, 2018), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.