This is the Final Report of the ''Multi-Pollutant Control Using Membrane-Based Up-flow Wet Electrostatic Precipitation'' project funded by the US Department of Energy's National Energy Technology Laboratory under DOE Award No. DE-FC26-02NT41592 to Croll-Reynolds Clean Air Technologies (CRCAT). In this 18 month project, CRCAT and its team members conducted detailed emission tests of metallic and new membrane collection material within a wet electrostatic precipitator (WESP) at First Energy's Penn Power's Bruce Mansfield (BMP) plant in Shippingport, Pa. The Membrane WESP was designed to be as similar as the metallic WESP in terms of collection area, air-flow, and electrical characteristics. Both …
continued below
Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.
Descriptive information to help identify this report.
Follow the links below to find similar items on the Digital Library.
Description
This is the Final Report of the ''Multi-Pollutant Control Using Membrane-Based Up-flow Wet Electrostatic Precipitation'' project funded by the US Department of Energy's National Energy Technology Laboratory under DOE Award No. DE-FC26-02NT41592 to Croll-Reynolds Clean Air Technologies (CRCAT). In this 18 month project, CRCAT and its team members conducted detailed emission tests of metallic and new membrane collection material within a wet electrostatic precipitator (WESP) at First Energy's Penn Power's Bruce Mansfield (BMP) plant in Shippingport, Pa. The Membrane WESP was designed to be as similar as the metallic WESP in terms of collection area, air-flow, and electrical characteristics. Both units are two-field units. The membrane unit was installed during the 2nd and 3rd quarters of 2003. Testing of the metallic unit was performed to create a baseline since the Mansfield plant had installed selective catalytic reduction equipment for NOx control and a sodium bisulfate injection system for SO3 control during the spring of 2003. Tests results on the metallic WESP were consistent with previous testing for PM2.5, SO3 mist and mercury. Testing on the membrane WESP demonstrated no adverse impact and equivalent removal efficiencies as that of the metallic WESP. Testing on both units was performed at 8,000 acfm and 15,000 acfm. Summary results are shown.
This report is part of the following collection of related materials.
Office of Scientific & Technical Information Technical Reports
Reports, articles and other documents harvested from the Office of Scientific and Technical Information.
Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.
Reynolds, James.MULTI-POLLUTANT CONTROL USING MEMBRANE--BASED UP-FLOW WET ELECTROSTATIC PRECIPITATION,
report,
October 29, 2004;
United States.
(https://digital.library.unt.edu/ark:/67531/metadc788581/:
accessed February 12, 2025),
University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu;
crediting UNT Libraries Government Documents Department.