Abstract: An alpha survey radiac employing a photomultiplier tube and scintillation detector has been developed. The instrument utilizes transistor circuitry and operates from two standard flashlight batteries. Four linear ranges are provided with full scale indication on the highest range corresponding to 10,000 g /m2 Pu2 39. The instrument was designed with .a separable probe and a telescoping extension for easier ground monitoring. A thorium metal source is attached to the instrument housing for checking instrument calibration in the field. The device conforms satisfactorily to the military requirements for altitude, humidity, vibration, shock, and storage. The operational battery life is …
continued below
Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.
Added Title:
U.S. Naval Radiological Defense Laboratory Report TR-326
Description
Abstract: An alpha survey radiac employing a photomultiplier tube and scintillation detector has been developed. The instrument utilizes transistor circuitry and operates from two standard flashlight batteries. Four linear ranges are provided with full scale indication on the highest range corresponding to 10,000 g /m2 Pu2 39. The instrument was designed with .a separable probe and a telescoping extension for easier ground monitoring. A thorium metal source is attached to the instrument housing for checking instrument calibration in the field. The device conforms satisfactorily to the military requirements for altitude, humidity, vibration, shock, and storage. The operational battery life is in excess of 40 hours. Instrument error at low temperatures slightly exceeds the 20% accuracy requirement; however, adequate measurements are readily made by using the thorium check source to provide a check point. Instrument response to low energy X-rays is excessive. However, tests indicate that a simple lead filter will eliminate this difficulty.
This report is part of the following collection of related materials.
Technical Report Archive and Image Library
The Technical Report Archive & Image Library (TRAIL) identifies, acquires, catalogs, digitizes and provides unrestricted access to U.S. government agency technical reports. The mission of TRAIL is to ensure preservation, discoverability, and persistent open access to government technical publications regardless of form or format.