Geothermal power plants are designed and constructed to provide a rated power output at specific resource and ambient conditions. Due to both diurnal and seasonal changes in the ambient air temperature, as well as a decline in resource productivity over time, plants seldom operate at these ''design'' conditions. This paper examines the impact of ''off- design'' operation of an air-cooled binary geothermal power plant. An available energy analysis is used to evaluate operation at these conditions. This evaluation identifies those portions of the power cycle that are most sensitive to changing resource and ambient conditions, as well as where improvements ... continued below

Physical Description

348 Kilobytes pages

Creation Information

Mines, G.L. June 17, 2002.

Context

This article is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this article can be viewed below.

Who

People and organizations associated with either the creation of this article or its content.

Author

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this article. Follow the links below to find similar items on the Digital Library.

Description

Geothermal power plants are designed and constructed to provide a rated power output at specific resource and ambient conditions. Due to both diurnal and seasonal changes in the ambient air temperature, as well as a decline in resource productivity over time, plants seldom operate at these ''design'' conditions. This paper examines the impact of ''off- design'' operation of an air-cooled binary geothermal power plant. An available energy analysis is used to evaluate operation at these conditions. This evaluation identifies those portions of the power cycle that are most sensitive to changing resource and ambient conditions, as well as where improvements in cycle component or system performance would have the largest impact in increasing power output.

Physical Description

348 Kilobytes pages

Notes

OSTI as DE00797777

Source

  • Geothermal Resources Council Annual Meeting, Reno, NV (US), 09/22/2002--09/25/2002

Language

Item Type

Identifier

Unique identifying numbers for this article in the Digital Library or other systems.

  • Report No.: INEEL/CON-02-00793
  • Grant Number: AC07-99ID13727
  • Office of Scientific & Technical Information Report Number: 797777
  • Archival Resource Key: ark:/67531/metadc743045

Collections

This article is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this article?

When

Dates and time periods associated with this article.

Creation Date

  • June 17, 2002

Added to The UNT Digital Library

  • Oct. 19, 2015, 7:39 p.m.

Description Last Updated

  • April 27, 2016, 2:53 p.m.

Usage Statistics

When was this article last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 4

Interact With This Article

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Mines, G.L. Evaluation of the Impact of Off-Design Operation on an Air-Cooled Binary Power Plant, article, June 17, 2002; Idaho Falls, Idaho. (digital.library.unt.edu/ark:/67531/metadc743045/: accessed November 22, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.