System Review of Safety Function Components for the Design of the Cask MCO Helium Purge System Project A.5 and A.6

PDF Version Also Available for Download.

Description

The design of the Cask/Multiple Canister Overpack (MCO) Helium Purge System (HPS) is assessed for the appropriate designated safety function classification of its components. The purpose of this review is to determine appropriate safety function classifications for the system's components or to identify actions to be taken to reasonably assure that the system/component safety function(s) will be performed as intended. This review also includes consideration that the HPS would perform consistent with its analytical assumptions and basis in HNF-2833, Rev. 0.

Physical Description

35 pages

Creation Information

LEW, B.S. March 27, 2000.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. It has been viewed 13 times . More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Author

Sponsor

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

The design of the Cask/Multiple Canister Overpack (MCO) Helium Purge System (HPS) is assessed for the appropriate designated safety function classification of its components. The purpose of this review is to determine appropriate safety function classifications for the system's components or to identify actions to be taken to reasonably assure that the system/component safety function(s) will be performed as intended. This review also includes consideration that the HPS would perform consistent with its analytical assumptions and basis in HNF-2833, Rev. 0.

Physical Description

35 pages

Notes

INIS; OSTI as DE00801890

Source

  • Other Information: PBD: 27 Mar 2000

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Report No.: SNF-5878, Rev.0
  • Grant Number: AC06-96RL13200
  • DOI: 10.2172/801890 | External Link
  • Office of Scientific & Technical Information Report Number: 801890
  • Archival Resource Key: ark:/67531/metadc742813

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • March 27, 2000

Added to The UNT Digital Library

  • Oct. 19, 2015, 7:39 p.m.

Description Last Updated

  • May 3, 2016, 4:37 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 13

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

LEW, B.S. System Review of Safety Function Components for the Design of the Cask MCO Helium Purge System Project A.5 and A.6, report, March 27, 2000; United States. (digital.library.unt.edu/ark:/67531/metadc742813/: accessed August 21, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.