PC and monitor night status: Power management enabling and manual turn-off

PDF Version Also Available for Download.

Description

While office equipment accounts for about 7 percent of commercial building energy use, this reflects considerable energy savings from the use of automatic power management. Most of these savings were gained through the use of low-power modes that meet the criteria of the U.S. EPA's Energy Star program. Despite this success, there are large amounts of additional savings that could be gained if all equipment capable of power management use were enabled and functioning. A considerable portion of equipment is not enabled for power management at all, enabled only partially, or is enabled but prevented from functioning. Additional savings could ... continued below

Physical Description

vp.

Creation Information

Nordman, Bruce; Meier, Alan & Piette, Mary Ann July 30, 1998.

Context

This article is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this article can be viewed below.

Who

People and organizations associated with either the creation of this article or its content.

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this article. Follow the links below to find similar items on the Digital Library.

Description

While office equipment accounts for about 7 percent of commercial building energy use, this reflects considerable energy savings from the use of automatic power management. Most of these savings were gained through the use of low-power modes that meet the criteria of the U.S. EPA's Energy Star program. Despite this success, there are large amounts of additional savings that could be gained if all equipment capable of power management use were enabled and functioning. A considerable portion of equipment is not enabled for power management at all, enabled only partially, or is enabled but prevented from functioning. Additional savings could be gained if more equipment were turned off at night manually. We compiled results from 17 studies from the office equipment literature addressing PCs and monitors. Some factors important for annual energy use, such as power levels, have been documented elsewhere and are not covered. We review methods for estimating office equipment use patterns and energy use, and present findings on night status--power management and manual turn-off rates. In early studies, PC power management was often found to function in 25 percent or less of the Energy Star compliant units (10 percent of all PCs). However, recent assessments have found higher rates, and we estimate that for Energy Star models, 35 percent of PC CPUs and 65 percent of PC monitors are enabled for power management. While the data lack statistical rigor, they can be used to estimate the magnitude of current and potential power management savings, which we did for major types of office equipment. The data also make clear that the topic of enabling rates, and the factors which influence them, deserve greater scrutiny.

Physical Description

vp.

Notes

OSTI as DE00795948

Source

  • 2000 ACEEE Summer Study On Energy Efficiency in Buildings, Pacific Grove, CA (US), 08/20/2000--08/25/2000

Language

Item Type

Identifier

Unique identifying numbers for this article in the Digital Library or other systems.

  • Report No.: LBNL--46099
  • Grant Number: AC03-76SF00098
  • Office of Scientific & Technical Information Report Number: 795948
  • Archival Resource Key: ark:/67531/metadc742721

Collections

This article is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

What responsibilities do I have when using this article?

When

Dates and time periods associated with this article.

Creation Date

  • July 30, 1998

Added to The UNT Digital Library

  • Oct. 19, 2015, 7:39 p.m.

Description Last Updated

  • April 4, 2016, 3:32 p.m.

Usage Statistics

When was this article last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 4

Interact With This Article

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Nordman, Bruce; Meier, Alan & Piette, Mary Ann. PC and monitor night status: Power management enabling and manual turn-off, article, July 30, 1998; Berkeley, California. (digital.library.unt.edu/ark:/67531/metadc742721/: accessed August 22, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.