The electron cooling project requires a high current electron beam with high reliability to provide the consistent cooling required by Fermilab's physics program. We are using a 5URE-2 Pelletron to provide this beam. The program is developing a high current DC recirculating electron beam with high recovery efficiency. The present layout uses 2 sets of tubes with acceleration, a 180{sup o} bend, and deceleration for a total of about 10 meters of beam line. The project's nominal operating parameters are .5 A at 4.3 MeV with the emission cathode immersed in a 200-600 G magnetic field.

Physical Description

25 Kilobytes pages

Creation Information

Kroc, Thomas K October 24, 2002.

Context

This article is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this article can be viewed below.

Who

People and organizations associated with either the creation of this article or its content.

Sponsor

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this article. Follow the links below to find similar items on the Digital Library.

Description

The electron cooling project requires a high current electron beam with high reliability to provide the consistent cooling required by Fermilab's physics program. We are using a 5URE-2 Pelletron to provide this beam. The program is developing a high current DC recirculating electron beam with high recovery efficiency. The present layout uses 2 sets of tubes with acceleration, a 180{sup o} bend, and deceleration for a total of about 10 meters of beam line. The project's nominal operating parameters are .5 A at 4.3 MeV with the emission cathode immersed in a 200-600 G magnetic field.

Physical Description

25 Kilobytes pages

Source

  • SNEAP 2002, Lafayette, LA (US), 10/07/2002--10/10/2002

Language

Item Type

Identifier

Unique identifying numbers for this article in the Digital Library or other systems.

  • Report No.: FERMILAB-Conf-02/242-E
  • Grant Number: AC02-76CH03000
  • Office of Scientific & Technical Information Report Number: 803407
  • Archival Resource Key: ark:/67531/metadc741832

Collections

This article is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

What responsibilities do I have when using this article?

When

Dates and time periods associated with this article.

Creation Date

  • October 24, 2002

Added to The UNT Digital Library

  • Oct. 19, 2015, 7:39 p.m.

Description Last Updated

  • April 1, 2016, 5:54 p.m.

Usage Statistics

When was this article last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 2

Interact With This Article

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Kroc, Thomas K. Status of the Fermilab electron cooling recirculation project, article, October 24, 2002; Batavia, Illinois. (digital.library.unt.edu/ark:/67531/metadc741832/: accessed August 19, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.