WSRC-TR-2002-00545
Immobilization Technology Section
Savannah River Technology Center
Westinghouse Savannah River CompanyB2. Temperature Profiles of the Higher Waste Loading Tests in the MRF
27% Waste Loading (Frit 320 + SB2)
1200
1000
2 800
600
400
C)
~ 200 ______
0-
0 5 10 15 20 25 30 35 40 45
Run time (minutes)
Furnace - 1/2" - 1" 2" - Va or 5"
29% Waste Loading (Frit 320 + SB2)
1200-
- 1000
800
1 600
Q 400 T__ _____
C)
~ 200 __ _ ______
0 5 10 15 20 25 30 35 40 45
Run time (minutes)
Furnace - 1/2" - 1" 2" - Va or 5"
31% Waste Loading (Frit 320 + SB2)
1200 __
-1000 _______________
800 __
S600
E 400
(D
~ 200 ___ _________
0
0 5 10 15 20 25 30 35 40 45
Run time (minutes)
Furnace -1/2" -1" 2" -Va or 5"38
Upcoming Pages
Here’s what’s next.
Search Inside
This report can be searched. Note: Results may vary based on the legibility of text within the document.
Tools / Downloads
Get a copy of this page or view the extracted text.
Citing and Sharing
Basic information for referencing this web page. We also provide extended guidance on usage rights, references, copying or embedding.
Reference the current page of this Report.
Lorier, T.H. Melt Rate Testing for the DWPF: Summary of FY02 Testing, report, February 19, 2003; South Carolina. (https://digital.library.unt.edu/ark:/67531/metadc740722/m1/50/: accessed April 25, 2024), University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu; crediting UNT Libraries Government Documents Department.