The results of several studies of the 200-MeV (LINAC), AGS (E880), and RHIC polarimeter data from the polarized proton run in 2001/2002 are presented. Much of this work occurred during or immediately after the run. Some of these analyses have implications for the understanding of the performance of the polarized ion source, AGS, and RHIC with polarized protons. Some of the conclusions include: (A) A recalibration of the 200-MeV polarimeter gives results consistent with the older calibration, but high rates in the 200-MeV polarimeter are still a problem. (B) No evidence of sizable systematic effects was found in several tests …
continued below
Publisher Info:
Argonne National Lab., IL (United States)
Place of Publication:
Illinois
Provided By
UNT Libraries Government Documents Department
Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.
Descriptive information to help identify this report.
Follow the links below to find similar items on the Digital Library.
Description
The results of several studies of the 200-MeV (LINAC), AGS (E880), and RHIC polarimeter data from the polarized proton run in 2001/2002 are presented. Much of this work occurred during or immediately after the run. Some of these analyses have implications for the understanding of the performance of the polarized ion source, AGS, and RHIC with polarized protons. Some of the conclusions include: (A) A recalibration of the 200-MeV polarimeter gives results consistent with the older calibration, but high rates in the 200-MeV polarimeter are still a problem. (B) No evidence of sizable systematic effects was found in several tests of the AGS polarimeter with a thin carbon fiber target. (C) Significant polarization loss in the AGS was observed above G{sub {gamma}} = 7.5 but not between injection and G{sub {gamma}} = 7.5. (D) The magnitude of the flattop asymmetry in the RHIC polarimeters decreases with time in a fill. (E) The RHIC polarimeter analyzing power on flattop is greater than or equal to that at injection. (F) Unexplained systematic effects were observed in the RHIC polarimeter, but the implications for the measured polarization asymmetry are not clear. These effects were not isolated events, but occurred throughout the run. Conceivably the data could indicate that the present RHIC polarimeter design will not be able to achieve a goal of a {+-} 5% measurement of the beam polarization.
This report is part of the following collection of related materials.
Office of Scientific & Technical Information Technical Reports
Reports, articles and other documents harvested from the Office of Scientific and Technical Information.
Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.
Bravar, A.; Bunce, G.; Cadman, R. V.; Huang, H.; Jinnouchi, O.; Krueger, K. et al.Analysis of polarimeter data for the 2001-2002 RHIC run.,
report,
December 22, 2003;
Illinois.
(https://digital.library.unt.edu/ark:/67531/metadc740571/:
accessed April 23, 2024),
University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu;
crediting UNT Libraries Government Documents Department.