Hazard Evaluation for the Saltwell Chempump and a Saltwell Centrifugal Pump Design using Service Water for Lubrication and Cooling

PDF Version Also Available for Download.

Description

This report documents results of a preliminary hazard analysis (PHA) covering the existing Crane Chempump and the new salt well pumping design. Three hazardous conditions were identified for the Chempump and ten hazardous conditions were identified for the new salt well pump design. This report also presents the results of the control decision/allocation process. A backflow preventer and associated limiting condition for operation were assigned to one hazardous condition with the new design.

Physical Description

87 pages

Creation Information

GRAMS, W.H. November 16, 2000.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. It has been viewed 49 times , with 14 in the last month . More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Author

Sponsor

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

This report documents results of a preliminary hazard analysis (PHA) covering the existing Crane Chempump and the new salt well pumping design. Three hazardous conditions were identified for the Chempump and ten hazardous conditions were identified for the new salt well pump design. This report also presents the results of the control decision/allocation process. A backflow preventer and associated limiting condition for operation were assigned to one hazardous condition with the new design.

Physical Description

87 pages

Notes

INIS; OSTI as DE00805639

Source

  • Other Information: PBD: 16 Nov 2000

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Report No.: RPP-6954, Rev.1
  • Grant Number: AC27-99RL14047
  • DOI: 10.2172/805639 | External Link
  • Office of Scientific & Technical Information Report Number: 805639
  • Archival Resource Key: ark:/67531/metadc738894

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • November 16, 2000

Added to The UNT Digital Library

  • Oct. 18, 2015, 6:40 p.m.

Description Last Updated

  • April 21, 2016, 6:35 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 14
Total Uses: 49

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

GRAMS, W.H. Hazard Evaluation for the Saltwell Chempump and a Saltwell Centrifugal Pump Design using Service Water for Lubrication and Cooling, report, November 16, 2000; United States. (digital.library.unt.edu/ark:/67531/metadc738894/: accessed September 22, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.