Assessment of MTI Water Temperature Thermal Discharge Retrievals with Ground Truth Page: 1 of 25
This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided to UNT Digital Library by the UNT Libraries Government Documents Department.
Extracted Text
The following text was automatically extracted from the image on this page using optical character recognition software:
WSRC-TR-2002-003 80
Assessment of MTI Water Temperature Thermal
Discharge Retrievals with Ground Truth
Taken in the Pilgrim Nuclear Power Station
WSRC-TR-2002-00380
Malcolm M. Pendergast* and Robert J. Kurzeja**
*SMP Enterprises
Martinez. GA
** Savannah River Technology Center
Westinghouse Savannah River Co.1
Upcoming Pages
Here’s what’s next.
Search Inside
This report can be searched. Note: Results may vary based on the legibility of text within the document.
Tools / Downloads
Get a copy of this page or view the extracted text.
Citing and Sharing
Basic information for referencing this web page. We also provide extended guidance on usage rights, references, copying or embedding.
Reference the current page of this Report.
Kurzeja, R.J. Assessment of MTI Water Temperature Thermal Discharge Retrievals with Ground Truth, report, December 6, 2002; South Carolina. (https://digital.library.unt.edu/ark:/67531/metadc737834/m1/1/: accessed April 19, 2024), University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu; crediting UNT Libraries Government Documents Department.