Transmission electron microscopy (TEM) at sub-Angstrom resolution is important for nanotechnology. Identifying atom positions requires appropriate resolution, the ability to separate distinct objects in images. With Cs corrected, the information limit of the TEM controls resolution. The OAM has demonstrated that a resolution of 0.78A is possible. The TEAM (transmission electron achromatic microscope) will be a TEM using hardware correction of Cs with a monochromator to improve its information limit beyond that of the OAM by improvement of the electron-beam energy spread. It is shown that A 300keV HRTEM TEAM does not require a Cc corrector to reach 0.5A as ... continued below

Physical Description

vp.

Creation Information

O'Keefe, Michael A. February 17, 2003.

Context

This article is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this article can be viewed below.

Who

People and organizations associated with either the creation of this article or its content.

Sponsor

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this article. Follow the links below to find similar items on the Digital Library.

Description

Transmission electron microscopy (TEM) at sub-Angstrom resolution is important for nanotechnology. Identifying atom positions requires appropriate resolution, the ability to separate distinct objects in images. With Cs corrected, the information limit of the TEM controls resolution. The OAM has demonstrated that a resolution of 0.78A is possible. The TEAM (transmission electron achromatic microscope) will be a TEM using hardware correction of Cs with a monochromator to improve its information limit beyond that of the OAM by improvement of the electron-beam energy spread. It is shown that A 300keV HRTEM TEAM does not require a Cc corrector to reach 0.5A as long as beam energy spread and objective-lens current ripple are lowered sufficiently. A lower-voltage TEAM will require stricter limits on objective-lens current ripple to reach the targeted 0.5A resolution. No improvement in HT ripple or noise is required to improve the information limit per se since the monochromator determines the energy spread in the beam. However, improved HT ripple and noise will improve the beam current statistics (number of electrons passing through the monochromator) by placing more of the electrons closer to the center of the energy-spread distribution

Physical Description

vp.

Notes

OSTI as DE00810869

Source

  • The VII InterAmerican Congress on Electron Microscopy/ VII Congreso InterAmericano de Microscopia Electronica, San Antonio, TX (US), 08/03/2003--08/07/2003

Language

Item Type

Identifier

Unique identifying numbers for this article in the Digital Library or other systems.

  • Report No.: LBNL--52191
  • Grant Number: AC03-76SF00098
  • Office of Scientific & Technical Information Report Number: 810869
  • Archival Resource Key: ark:/67531/metadc737623

Collections

This article is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this article?

When

Dates and time periods associated with this article.

Creation Date

  • February 17, 2003

Added to The UNT Digital Library

  • Oct. 18, 2015, 6:40 p.m.

Description Last Updated

  • June 15, 2016, 1:07 p.m.

Usage Statistics

When was this article last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 2

Interact With This Article

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

International Image Interoperability Framework

IIF Logo

We support the IIIF Presentation API

O'Keefe, Michael A. HRTEM at half-Angstrom resolution: From OAM to TEAM, article, February 17, 2003; Berkeley, California. (digital.library.unt.edu/ark:/67531/metadc737623/: accessed May 26, 2018), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.