Characterization of HLW and LAW Glass Formers - Final Report

PDF Version Also Available for Download.

Description

A basis of thirteen glass former chemicals (GFCs) was selected upon reviewing existing River Protection Program - Waste Treatment Plant (RPP-WTP) subcontractor documents and after discussions with RPP-WTP R and T, Vitreous State Laboratory (VSL) and Savannah River Technology Center (SRTC) personnel. The thirteen baseline GFCs were approved by RPP-WTP R and T for future use in all RPP-WTP R and T test programs. SRTC established a contract with Jenike and Johanson Incorporated (J and J), a material handling consultant, to perform the following work scope: (1) Measure and report the physical and flow properties of the thirteen individual GFCs, ... continued below

Physical Description

vp.

Creation Information

Schumacher, R.F. October 3, 2003.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Sponsor

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

A basis of thirteen glass former chemicals (GFCs) was selected upon reviewing existing River Protection Program - Waste Treatment Plant (RPP-WTP) subcontractor documents and after discussions with RPP-WTP R and T, Vitreous State Laboratory (VSL) and Savannah River Technology Center (SRTC) personnel. The thirteen baseline GFCs were approved by RPP-WTP R and T for future use in all RPP-WTP R and T test programs. SRTC established a contract with Jenike and Johanson Incorporated (J and J), a material handling consultant, to perform the following work scope: (1) Measure and report the physical and flow properties of the thirteen individual GFCs, three representative Low Activity Waste (LAW) GFC blends, and two representative High Level Waste (HLW) GFC blends under ''as received'' and ''at rest'' conditions. The data obtained from these tests will be used for ''information only.'' (2) Review the conceptual design of the RPP-WTP bulk solids handling system. (3) Provide functional design parameters needed to achieve mass flow or expanded flow in all 13 storage silos. (4) Provide recommendations on the delivery of blended GFCs to the Melter Feed Preparation Vessels (MFPV). (5) Provide general recommendations on bulk solids handling issues. Jenike and Johanson completed this work and issued two technical reports providing their results and recommendations. Their findings and conclusions are summarized and presented in this report.

Physical Description

vp.

Source

  • Other Information: PBD: 3 Oct 2003

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Report No.: WSRC-TR-2002-00282, Rev. 1
  • Grant Number: AC09-96SR18500
  • DOI: 10.2172/816093 | External Link
  • Office of Scientific & Technical Information Report Number: 816093
  • Archival Resource Key: ark:/67531/metadc734437

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • October 3, 2003

Added to The UNT Digital Library

  • Oct. 18, 2015, 6:40 p.m.

Description Last Updated

  • May 4, 2016, 9:34 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 3

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Schumacher, R.F. Characterization of HLW and LAW Glass Formers - Final Report, report, October 3, 2003; South Carolina. (digital.library.unt.edu/ark:/67531/metadc734437/: accessed September 20, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.