CDF would like to install high precision track detectors. There is ample room on A-sector side, but space needs to be created at B11. The favored plan is to shove the first 3 B11 dipoles inwards toward the IP by 2.274 m. This would require removal of the inert Q1 quadrupole and its spool plus an extensive number of other mechanical and cryogenic modifications. The orbit distortion these modifications introduce would then be compensated by shifting the six B16 and B17 dipoles outwards by about half that amount. Space for this dipole move could be generated by replacing the 72 ... continued below

Physical Description

944 Kilobytes pages

Creation Information

Johnstone, John A. August 16, 2001.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Sponsor

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

CDF would like to install high precision track detectors. There is ample room on A-sector side, but space needs to be created at B11. The favored plan is to shove the first 3 B11 dipoles inwards toward the IP by 2.274 m. This would require removal of the inert Q1 quadrupole and its spool plus an extensive number of other mechanical and cryogenic modifications. The orbit distortion these modifications introduce would then be compensated by shifting the six B16 and B17 dipoles outwards by about half that amount. Space for this dipole move could be generated by replacing the 72 inch spool at B18 with a short 43 inch spool, and removing the 16.5 inch spacer after B17-5. The above scheme certainly recloses the orbit, and doesn't require the detector to move. However, by moving the B16 and B17 dipoles, the B17 and B18 arc quadrupoles also get shifted downstream--B17 by 1.115 m, and B18 by 0.696 m. Longitudinal movements of arc quads by such large fractions of their magnetic lengths will clearly impact the overall machine optics.

Physical Description

944 Kilobytes pages

Source

  • Other Information: PBD: 16 Aug 2001

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Report No.: FERMILAB-TM-2157
  • Grant Number: AC02-76CH03000
  • DOI: 10.2172/784419 | External Link
  • Office of Scientific & Technical Information Report Number: 784419
  • Archival Resource Key: ark:/67531/metadc724794

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • August 16, 2001

Added to The UNT Digital Library

  • Sept. 29, 2015, 5:31 a.m.

Description Last Updated

  • April 1, 2016, 6 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 2

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Johnstone, John A. Tevatron optics with magnet moves for Roman pots at CDF, report, August 16, 2001; Batavia, Illinois. (digital.library.unt.edu/ark:/67531/metadc724794/: accessed October 19, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.