Two optimum defocus conditions are used in high-resolution transmission electron microscopy. Scherzer defocus produces an image of the specimen ''projected potential'' to the resolution of the microscope, and Lichte defocus minimizes dispersion. A third optimum defocus is best for focal-series reconstruction; alpha-null defocus maximizes transfer of high-frequency diffracted beam amplitudes into the microscope image. Beam transfer is confined by incident-beam convergence to a Gaussian ''packet'' of defocus values centered on the alpha-null defocus. For a diffracted beam hkl, with a spatial frequency of u, the envelope for incident beam convergence has null damping effect when defocus is set to -Cs. ... continued below

Physical Description

vp.

Creation Information

O'Keefe, Michael A. February 14, 2001.

Context

This article is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this article can be viewed below.

Who

People and organizations associated with either the creation of this article or its content.

Sponsor

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this article. Follow the links below to find similar items on the Digital Library.

Description

Two optimum defocus conditions are used in high-resolution transmission electron microscopy. Scherzer defocus produces an image of the specimen ''projected potential'' to the resolution of the microscope, and Lichte defocus minimizes dispersion. A third optimum defocus is best for focal-series reconstruction; alpha-null defocus maximizes transfer of high-frequency diffracted beam amplitudes into the microscope image. Beam transfer is confined by incident-beam convergence to a Gaussian ''packet'' of defocus values centered on the alpha-null defocus. For a diffracted beam hkl, with a spatial frequency of u, the envelope for incident beam convergence has null damping effect when defocus is set to -Cs. (wavelength.u)**2. On either side of this alpha-null defocus value, the damping effect of incident-beam convergence reduces diffracted-beam transfer. The position of alpha-null defocus for any spatial frequency depends only on the value of Cs, but defocus-packet width around the alpha-null defocus depends only on the convergence semi-angle. Under NCEM OAM (one-Angstrom microscope) conditions, a [110] diamond image with the correct 0.89A spacing appears when the Si (004) alpha-null defocus is selected. The alpha-null defocus should be included as the (furthest underfocus) limit for all high-resolution focal series reconstruction.

Physical Description

vp.

Notes

OSTI as DE00789146

Source

  • Microscopy and Microanalysis 2001 -- 59th Annual Meeting MSA -- 35th Annual Meeting MSA, Long Beach, CA (US), 08/05/2001--08/09/2001

Language

Item Type

Identifier

Unique identifying numbers for this article in the Digital Library or other systems.

  • Report No.: LBNL--47532
  • Grant Number: AC03-76SF00098
  • Office of Scientific & Technical Information Report Number: 789146
  • Archival Resource Key: ark:/67531/metadc723804

Collections

This article is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this article?

When

Dates and time periods associated with this article.

Creation Date

  • February 14, 2001

Added to The UNT Digital Library

  • Sept. 29, 2015, 5:31 a.m.

Description Last Updated

  • April 4, 2016, 2:49 p.m.

Usage Statistics

When was this article last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 3

Interact With This Article

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

O'Keefe, Michael A. Alpha-null defocus: An optimum defocus condition with relevance for focal-series reconstruction, article, February 14, 2001; Berkeley, California. (digital.library.unt.edu/ark:/67531/metadc723804/: accessed November 20, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.