The CDF Layer 00 detector consists of single-sided silicon sensors assembled on the beampipe, forming the innermost of eight silicon layers in the CDF detector for Run II of the Fermilab Tevatron. Radiation tolerant p-in-n silicon with 25(50) {micro}m implant(readout) pitch are mounted on a lightweight, cooled support structure and connect to electronics outside the tracking volume via long, fine-pitch cables. Layer 00 will significantly improve the impact parameter resolution and enhance the longevity of the silicon system, benefiting a large portion of the physics program for Run II.

Physical Description

112 Kilobytes pages

Creation Information

Nelson, Timothy K. December 7, 2001.

Context

This article is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this article can be viewed below.

Who

People and organizations associated with either the creation of this article or its content.

Sponsor

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this article. Follow the links below to find similar items on the Digital Library.

Description

The CDF Layer 00 detector consists of single-sided silicon sensors assembled on the beampipe, forming the innermost of eight silicon layers in the CDF detector for Run II of the Fermilab Tevatron. Radiation tolerant p-in-n silicon with 25(50) {micro}m implant(readout) pitch are mounted on a lightweight, cooled support structure and connect to electronics outside the tracking volume via long, fine-pitch cables. Layer 00 will significantly improve the impact parameter resolution and enhance the longevity of the silicon system, benefiting a large portion of the physics program for Run II.

Physical Description

112 Kilobytes pages

Source

  • Meeting of the Division of Particles and Fields (DPF 2000) of the American Physical Society, Ohio State University, Columbus, OH (US), 08/09/2000--08/12/2000

Language

Item Type

Identifier

Unique identifying numbers for this article in the Digital Library or other systems.

  • Report No.: FERMILAB-Conf-357-E
  • Grant Number: AC02-76CH03000
  • Office of Scientific & Technical Information Report Number: 789367
  • Archival Resource Key: ark:/67531/metadc723100

Collections

This article is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

What responsibilities do I have when using this article?

When

Dates and time periods associated with this article.

Creation Date

  • December 7, 2001

Added to The UNT Digital Library

  • Sept. 29, 2015, 5:31 a.m.

Description Last Updated

  • April 1, 2016, 3:42 p.m.

Usage Statistics

When was this article last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 2

Interact With This Article

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Nelson, Timothy K. The CDF layer 00 detector, article, December 7, 2001; Batavia, Illinois. (digital.library.unt.edu/ark:/67531/metadc723100/: accessed September 21, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.