BEAM EMITTANCE DIAGNOSTIC FOR THE DARHT SECOND AXIS INJECTOR

PDF Version Also Available for Download.

Description

Low beam emittance is key to achieving the required spot size at the output focus of the DARHT Second Axis. The nominal electron beam parameters at the output of the injector are 2 kA, 4.6 MeV, 2-microsecond pulse width and an rms radius less than 1 cm. Emittance is measured by bringing the beam to a focus in which the emittance is a dominant influence in determining the spot size. The spot size is measured from Cerenkov or optical transition radiation (OTR) generated from a target intercepted by the beam. The current density in the focused DARHT beam would melt ... continued below

Physical Description

250 Kilobytes pages

Creation Information

BARTSCH, R.; EKDAHL, C. & AL, ET June 1, 2001.

Context

This article is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this article can be viewed below.

Who

People and organizations associated with either the creation of this article or its content.

Sponsor

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this article. Follow the links below to find similar items on the Digital Library.

Description

Low beam emittance is key to achieving the required spot size at the output focus of the DARHT Second Axis. The nominal electron beam parameters at the output of the injector are 2 kA, 4.6 MeV, 2-microsecond pulse width and an rms radius less than 1 cm. Emittance is measured by bringing the beam to a focus in which the emittance is a dominant influence in determining the spot size. The spot size is measured from Cerenkov or optical transition radiation (OTR) generated from a target intercepted by the beam. The current density in the focused DARHT beam would melt this target in less than 1/2 microsec. To prevent this we have designed a DC magnetic transport system that defocuses the beam on the emittance target to prevent overheating, and uses a 125-ns half period pulsed solenoid to selectively focus the beam for short times during the beam pulse. During the development of the fast-focusing portion of this diagnostic it has been determined that the focusing pulse must rapidly sweep through the focus at the target to an over-focused condition to avoid target damage due to overheating. The fast focus produces {approx}1 kilogauss field over an effective length of {approx}50 cm to bring the beam to a focus on the target. The fast focus field is generated with a 12-turn coil located inside the beam-transport vacuum chamber with the entire fast coil structure within the bore of a D.C. magnet. The pulsed coil diameter of {approx}15 cm is dictated by the return current path at the nominal vacuum wall. Since the drive system is to use 40 kV to 50 kV technology and much of the inductance is in the drive and feed circuit, the coil design has three 120 degree segments. The coil, driver and feed system design, as well as beam envelope calculations and target heating calculations are presented below. Operation of the OTR imaging system will be discussed in separate publication (Ref. 1).

Physical Description

250 Kilobytes pages

Source

  • Conference title not supplied, Conference location not supplied, Conference dates not supplied

Language

Item Type

Identifier

Unique identifying numbers for this article in the Digital Library or other systems.

  • Report No.: LA-UR-01-3050
  • Grant Number: W-7405-ENG-36
  • Office of Scientific & Technical Information Report Number: 783155
  • Archival Resource Key: ark:/67531/metadc719985

Collections

This article is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

What responsibilities do I have when using this article?

When

Dates and time periods associated with this article.

Creation Date

  • June 1, 2001

Added to The UNT Digital Library

  • Sept. 29, 2015, 5:31 a.m.

Description Last Updated

  • March 11, 2016, 1:43 p.m.

Usage Statistics

When was this article last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 2

Interact With This Article

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

BARTSCH, R.; EKDAHL, C. & AL, ET. BEAM EMITTANCE DIAGNOSTIC FOR THE DARHT SECOND AXIS INJECTOR, article, June 1, 2001; New Mexico. (digital.library.unt.edu/ark:/67531/metadc719985/: accessed August 21, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.