Characterization of a Washed 241-C-106 Sludge Sample

PDF Version Also Available for Download.

Description

An Envelope D Tank 241-C-106 sample was characterized for solids, elemental, and radioactive isotope content. The work was done by the Savannah River Technology Center (SRTC) to support the Hanford River Protection Project (RPP). The sludge from Hanford Tank 241-C-106 is high level waste that is to be included in the first ten years of processing by the RPP Waste Treatment Plant (WTP). The sample was a composite of caustic-leached and washed sludge from previous work at the Pacific Northwest National Lab (PNNL). Sludge analysis results were found to compare well with those of previous researchers analyzing leached samples from ... continued below

Physical Description

vp.

Creation Information

Nash, C.A. May 15, 2001.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Author

Sponsor

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

An Envelope D Tank 241-C-106 sample was characterized for solids, elemental, and radioactive isotope content. The work was done by the Savannah River Technology Center (SRTC) to support the Hanford River Protection Project (RPP). The sludge from Hanford Tank 241-C-106 is high level waste that is to be included in the first ten years of processing by the RPP Waste Treatment Plant (WTP). The sample was a composite of caustic-leached and washed sludge from previous work at the Pacific Northwest National Lab (PNNL). Sludge analysis results were found to compare well with those of previous researchers analyzing leached samples from Tank 241-C-106. Composition of the liquid accompanying the sample was also measured.

Physical Description

vp.

Source

  • Other Information: PBD: 15 May 2001

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Report No.: WSRC-TR-2001-00013
  • Grant Number: AC09-96SR18500
  • DOI: 10.2172/780978 | External Link
  • Office of Scientific & Technical Information Report Number: 780978
  • Archival Resource Key: ark:/67531/metadc719720

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • May 15, 2001

Added to The UNT Digital Library

  • Sept. 29, 2015, 5:31 a.m.

Description Last Updated

  • May 5, 2016, 3:42 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 2

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Nash, C.A. Characterization of a Washed 241-C-106 Sludge Sample, report, May 15, 2001; South Carolina. (digital.library.unt.edu/ark:/67531/metadc719720/: accessed August 20, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.