Cost Reduction and Manufacture of the SunSine{reg_sign} ac Module: Final Subcontract Report, 11 June 2001

PDF Version Also Available for Download.

Description

This project was a two-phase effort consisting of technical research and manufacturing development to improve and reduce the costs of the SunSine{reg_sign} inverter. Research addressed packaging, soft switching, circuit optimization, manufacturing process improvements, and pilot production manufacturing. Significant cost reductions were achieved. The main goal of this project was to reduce cost and improve the manufacturability and reliability of the SunSine{reg_sign} ac module, which consists of a SunSine{reg_sign} inverter mounted on an ASE Americas PV laminate. This work has also boosted the performance and enhanced marketability by adding customer-valued features. Ascension Technology has accomplished these advancements by cost reductions or ... continued below

Physical Description

vp.

Creation Information

Kern, G. & Russell, M. July 10, 2001.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Sponsor

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

This project was a two-phase effort consisting of technical research and manufacturing development to improve and reduce the costs of the SunSine{reg_sign} inverter. Research addressed packaging, soft switching, circuit optimization, manufacturing process improvements, and pilot production manufacturing. Significant cost reductions were achieved. The main goal of this project was to reduce cost and improve the manufacturability and reliability of the SunSine{reg_sign} ac module, which consists of a SunSine{reg_sign} inverter mounted on an ASE Americas PV laminate. This work has also boosted the performance and enhanced marketability by adding customer-valued features. Ascension Technology has accomplished these advancements by cost reductions or design modifications in the following areas: Die-cast aluminum enclosure and base plate; soft switching for cost reduction and efficiency gains; circuit board and component optimization for performance gains and size reduction; streamlined inverter assembly and production testing; and streamlined inverter/module assembly. As a result of the effort in these areas, Ascension Technology's objectives were to achieve the following: 40%-50% reduction in inverter manufacturing costs; 40% reduction in inverter size from 169 to 100 square inches; 4% increase in peak inverter efficiency from 87% to 91% at full power; UL listing, FCC certification; establish a production capability of 5000 SunSine{reg_sign} inverters/year through manufacturing improvements and production-line design improvements; less than 1 failure per 1000 units at time of installation/turn-on; a 5-year warranty; and a rating of 250 Wac at PTC for the SunSine{reg_sign} ac Module. Accomplishments during this project include: Inverter production costs were reduced 32% in the pilot production run; inverter production costs anticipated to be reduced a total of 36% in future production runs; 45% reduction in inverter footprint (in contact with module) from 169 to 93 square inches; and a 2.3% increase in inverter efficiency from 85.7% to 88.0% at full power. In addition, the SunSine{reg_sign} ac module is UL listed, meets IEEE Std. 929-2000, IEEE-C62.41-1991, IEEE-C62.45-1992, and NY State SIR requirements, and was verified to comply with FCC Class B EMI limits. There were 4 failures per 214 units at time of installation/turn-on; a 5-year inverter warranty is offered; and a rating of 235 Wac at PTC for the SunSine{reg_sign} ac module was achieved.

Physical Description

vp.

Source

  • Other Information: PBD: 10 Jul 2001

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Report No.: NREL/SR-520-30534
  • Grant Number: AC36-99GO10337
  • DOI: 10.2172/786353 | External Link
  • Office of Scientific & Technical Information Report Number: 786353
  • Archival Resource Key: ark:/67531/metadc718400

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • July 10, 2001

Added to The UNT Digital Library

  • Sept. 29, 2015, 5:31 a.m.

Description Last Updated

  • March 28, 2016, 12:16 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 3

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Kern, G. & Russell, M. Cost Reduction and Manufacture of the SunSine{reg_sign} ac Module: Final Subcontract Report, 11 June 2001, report, July 10, 2001; Golden, Colorado. (digital.library.unt.edu/ark:/67531/metadc718400/: accessed August 22, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.