Energy Vernier System for CEBAF

PDF Version Also Available for Download.

Description

The beam energy of CEBAF must be accurately controlled for precise physics experiments. In order to achieve a relative energy spread better than sigma{sub E}/E = 2.5 x 10{sup -5}, a feedback system is needed to stabilize the energy against phase and amplitude fluctuations in the individual cavities. In the energy vernier system, the energy deviation of the beam is measured at a location with high dispersion. The error signal controls the accelerating gradient of selected vernier cavities. The methods used to correct the energy will be discussed, as well as the noise sources in the system. The results of ... continued below

Physical Description

213 Kilobytes pages

Creation Information

Krafft, G. A.; Bisognano, J. J.; Crofford, M. T.; Hovater, C.; Merminga, L.; Simrock, S. N. et al. May 1, 1993.

Context

This article is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this article can be viewed below.

Who

People and organizations associated with either the creation of this article or its content.

Sponsor

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this article. Follow the links below to find similar items on the Digital Library.

Description

The beam energy of CEBAF must be accurately controlled for precise physics experiments. In order to achieve a relative energy spread better than sigma{sub E}/E = 2.5 x 10{sup -5}, a feedback system is needed to stabilize the energy against phase and amplitude fluctuations in the individual cavities. In the energy vernier system, the energy deviation of the beam is measured at a location with high dispersion. The error signal controls the accelerating gradient of selected vernier cavities. The methods used to correct the energy will be discussed, as well as the noise sources in the system. The results of beam tests at the CEBAF north linac will also be reported.

Physical Description

213 Kilobytes pages

Source

  • PAC 1993, Washington, DC (US), 05/17/1993--05/20/1993

Language

Item Type

Identifier

Unique identifying numbers for this article in the Digital Library or other systems.

  • Report No.: CEBAF-PR-93-037
  • Report No.: DOE/ER/40150-1921
  • Grant Number: AC05-84ER40150
  • Office of Scientific & Technical Information Report Number: 787850
  • Archival Resource Key: ark:/67531/metadc717288

Collections

This article is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

What responsibilities do I have when using this article?

When

Dates and time periods associated with this article.

Creation Date

  • May 1, 1993

Added to The UNT Digital Library

  • Sept. 29, 2015, 5:31 a.m.

Description Last Updated

  • Feb. 5, 2016, 8:04 p.m.

Usage Statistics

When was this article last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 2

Interact With This Article

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Krafft, G. A.; Bisognano, J. J.; Crofford, M. T.; Hovater, C.; Merminga, L.; Simrock, S. N. et al. Energy Vernier System for CEBAF, article, May 1, 1993; Newport News, Virginia. (digital.library.unt.edu/ark:/67531/metadc717288/: accessed September 26, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.