Abstract: Isotope ratios for plutonium can be determined through direct observation of atomic emission spectra at high resolution. The plutonium atomic line at 594.52202 nm has been previously catalogued with a Pu-240/Pu-239 isotope shift of -0.355 wavenumbers using a microwave electrodeless discharge tube and a 9-m photographic plate emission spectrograph. This isotope shift has now been clearly resolved from a laser induced plasma. Atomic emission was dispersed through a 2-m spectrometer in double pass mode and collected on an electronically gated, intensified charge-coupled device (ICCD) camera. Curve-fitting software was used to produce integrated peak areas where ratios closely match known ... continued below

Physical Description

13 p.

Creation Information

Smith, Coleman A.; Martinez, Max A. & Veirs, D. Kirk September 2000.

Context

This article is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this article can be viewed below.

Who

People and organizations associated with either the creation of this article or its content.

Authors

Sponsor

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this article. Follow the links below to find similar items on the Digital Library.

Description

Abstract: Isotope ratios for plutonium can be determined through direct observation of atomic emission spectra at high resolution. The plutonium atomic line at 594.52202 nm has been previously catalogued with a Pu-240/Pu-239 isotope shift of -0.355 wavenumbers using a microwave electrodeless discharge tube and a 9-m photographic plate emission spectrograph. This isotope shift has now been clearly resolved from a laser induced plasma. Atomic emission was dispersed through a 2-m spectrometer in double pass mode and collected on an electronically gated, intensified charge-coupled device (ICCD) camera. Curve-fitting software was used to produce integrated peak areas where ratios closely match known isotope ratios. Observed plutonium linewidths were on the order of 0.0066 nm. The instrument-limited linewidth was calculated to be 0.0052 nm, based upon the known modulation transfer function for the ICCD system.

Physical Description

13 p.

Notes

OSTI as DE00764623

Medium: P; Size: vp.

Source

  • LASER INDUCED PLASMA SPECTROSCOPY AND APPLICATIONS, PISA (IT), 10/08/2000--10/12/2000

Language

Item Type

Identifier

Unique identifying numbers for this article in the Digital Library or other systems.

  • Report No.: LA-UR-00-4578
  • Grant Number: W-7405-ENG-36
  • Office of Scientific & Technical Information Report Number: 764623
  • Archival Resource Key: ark:/67531/metadc717050

Collections

This article is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

What responsibilities do I have when using this article?

When

Dates and time periods associated with this article.

Creation Date

  • September 2000

Added to The UNT Digital Library

  • Sept. 29, 2015, 5:31 a.m.

Description Last Updated

  • March 1, 2016, 6:27 p.m.

Usage Statistics

When was this article last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 5

Interact With This Article

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Smith, Coleman A.; Martinez, Max A. & Veirs, D. Kirk. PU-239/PU-240 ISOTOPE RATIOS DETERMINED USING HIGH RESOLUTION EMISSION SPECTROSCOPY IN A LASER INDUCED PLASMA, article, September 2000; New Mexico. (digital.library.unt.edu/ark:/67531/metadc717050/: accessed August 18, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.