Abstract: Experimentally measured promp-neutron decay constants for sub-critical systems are of considerable value as normalization data for calculations of prompt-neutron time constants. A method of measuring these decay constants with a pulsed neutron source, neutron detector and multi-channel time-delay analyzer has been developed and used on a number of fast-spectrum subcritical systems. An analysis of this method based on the one-energy group, one-delayed-neutron group reactor kinetic equations is presented and discussed. The curve of neutron flux versus time predicted by the kinetic equations is compared with the observed curve obtained with a 13.1-cm. diam. enriched-uranium sphere to indicate the application …
continued below
We've identified this
report
as a primary source within our collections. Researchers, educators, and students may find this report useful in their work.
Provided By
UNT Libraries Government Documents Department
Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.
Added Title:
University of California Radiation Laboratory Report UCRL-4808
Description
Abstract: Experimentally measured promp-neutron decay constants for sub-critical systems are of considerable value as normalization data for calculations of prompt-neutron time constants. A method of measuring these decay constants with a pulsed neutron source, neutron detector and multi-channel time-delay analyzer has been developed and used on a number of fast-spectrum subcritical systems. An analysis of this method based on the one-energy group, one-delayed-neutron group reactor kinetic equations is presented and discussed. The curve of neutron flux versus time predicted by the kinetic equations is compared with the observed curve obtained with a 13.1-cm. diam. enriched-uranium sphere to indicate the application and limitations of the analysis.
This report is part of the following collections of related materials.
Technical Report Archive and Image Library
The Technical Report Archive & Image Library (TRAIL) identifies, acquires, catalogs, digitizes and provides unrestricted access to U.S. government agency technical reports. The mission of TRAIL is to ensure preservation, discoverability, and persistent open access to government technical publications regardless of form or format.
Imaged from microcard, these technical reports describe research performed for U.S. government agencies from the 1930s to the 1960s. The reports were provided by the Technical Report Archive and Image Library (TRAIL).
Passell, Lawrence; Bengston, Joel & Blair, Donald C.The Application of Pulsed Neutron Sources to Criticality Measurements,
report,
January 30, 1957;
Washington D.C..
(https://digital.library.unt.edu/ark:/67531/metadc714785/:
accessed July 16, 2025),
University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu;
crediting UNT Libraries Government Documents Department.