Mixer pump test plan for double shell tank AZ-101

PDF Version Also Available for Download.

Description

Westinghouse Hanford Company has undertaken the task to develop and demonstrate a method of retrieval for double-shell tank (DST)waste. Mixer pumps were chosen as the planned method of retrieval for the DSTs, based on engineering technology studies,past experience with hydraulic sluicing at the Hanford Site, and experience with mixer pumps at the Westinghouse Savannah River Site. This document outlines a test plan to demonstrate the ability of two 300 hp mixer pumps installed in the AZ-101 tank to mobilize waste.

Physical Description

25 p.

Creation Information

Symons, G.A. & Staehr, T.W., Westinghouse Hanford June 1, 1996.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Sponsor

Publisher

  • Westinghouse Hanford Company
    Publisher Info: Westinghouse Hanford Co., Richland, WA (United States)
    Place of Publication: Richland, Washington

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

Westinghouse Hanford Company has undertaken the task to develop and demonstrate a method of retrieval for double-shell tank (DST)waste. Mixer pumps were chosen as the planned method of retrieval for the DSTs, based on engineering technology studies,past experience with hydraulic sluicing at the Hanford Site, and experience with mixer pumps at the Westinghouse Savannah River Site. This document outlines a test plan to demonstrate the ability of two 300 hp mixer pumps installed in the AZ-101 tank to mobilize waste.

Physical Description

25 p.

Notes

OSTI as DE98054384

Source

  • Other Information: PBD: 1 Jun 1996

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Other: DE98054384
  • Report No.: WHC-SD-WM-PTP--027-Rev.2
  • Grant Number: AC06-96RL13200
  • DOI: 10.2172/659250 | External Link
  • Office of Scientific & Technical Information Report Number: 659250
  • Archival Resource Key: ark:/67531/metadc711653

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • June 1, 1996

Added to The UNT Digital Library

  • Sept. 12, 2015, 6:31 a.m.

Description Last Updated

  • June 14, 2016, 3:44 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 2
Total Uses: 8

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

International Image Interoperability Framework

IIF Logo

We support the IIIF Presentation API

Symons, G.A. & Staehr, T.W., Westinghouse Hanford. Mixer pump test plan for double shell tank AZ-101, report, June 1, 1996; Richland, Washington. (digital.library.unt.edu/ark:/67531/metadc711653/: accessed October 16, 2018), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.