Field tests of X-ray backscatter mine detection Metadata
Metadata describes a digital item, providing (if known) such information as creator, publisher, contents, size, relationship to other resources, and more. Metadata may also contain "preservation" components that help us to maintain the integrity of digital files over time.
Title
- Main Title Field tests of X-ray backscatter mine detection
Creator
-
Author: Lockwood, G. J.Creator Type: Personal
-
Author: Shope, S. L.Creator Type: Personal
-
Author: Wehlburg, J. C.Creator Type: Personal
-
Author: Selph, M. M.Creator Type: Personal
-
Author: Jojola, J. M.Creator Type: Personal
-
Author: Turman, B. N.Creator Type: PersonalCreator Info: Sandia National Labs., Albuquerque, NM (United States)
-
Author: Jacobs, J. A.Creator Type: PersonalCreator Info: Univ. of Florida, Gainesville, FL (United States)
Contributor
-
Sponsor: United States. Department of Energy.Contributor Type: OrganizationContributor Info: USDOE, Washington, DC (United States)
Publisher
-
Name: Sandia National LaboratoriesPlace of Publication: Albuquerque, New MexicoAdditional Info: Sandia National Labs., Albuquerque, NM (United States)
Date
- Creation: 1998-08-01
Language
- English
Description
- Content Description: The implementation of a backscattered X-ray landmine detection system has been demonstrated in laboratories at both Sandia National Laboratories (SNL) and the University of Florida (UF). To assess the system`s response to a variety of objects, buried plastic and metal antitank landmines, surface plastic antipersonnel landmines, and surface metal fragments were used as targets. The X-ray machine used for the field test system was an industrial X-ray machine which was operated at 150 kV and 5 mZ and collimated to create a 2 cm diameter X-ray spot on the soil. The detectors used were two plastic scintillation detectors: one collimated to respond primarily to photons that have undergone multiple collision and the other uncollimated to respond primarily to photons that have had only one collision. To provide motion, the system was mounted on a gantry and rastered side-to-side using a computer-controlled stepper motor with a come-along providing the forward movement. Data generated from the detector responses were then analyzed to provide the images and locations of landmines. A new analysis method that increases resolution was used. Changing from the lab environment to the field did not decrease the system`s ability to detect buried or obscured landmines. The addition of rain, blowing dust, rocky soil and native plant-life did not lower the system`s resolution or contrast for the plastic or the metal landmines. Concepts for a civilian mine detection system based on this work using commercial off the shelf (COTS) equipment were developed.
- Physical Description: 4 p.
Subject
- Keyword: Scintillation Counters
- Keyword: Backscattering
- Keyword: Underground Facilities
- Keyword: X Radiation
- Keyword: Detection
- Keyword: Bombs
- Keyword: Performance
- STI Subject Categories: 45 Military Technology, Weaponry, And National Defense
- Keyword: Field Tests
Source
- Conference: 2. international conference on detection of abandoned land mines, Edinburgh (United Kingdom), 12-14 Oct 1998
Collection
-
Name: Office of Scientific & Technical Information Technical ReportsCode: OSTI
Institution
-
Name: UNT Libraries Government Documents DepartmentCode: UNTGD
Resource Type
- Article
Format
- Text
Identifier
- Other: DE98007155
- Report No.: SAND--98-1153C
- Report No.: CONF-981008--
- Grant Number: AC04-94AL85000
- Office of Scientific & Technical Information Report Number: 665980
- Archival Resource Key: ark:/67531/metadc710584
Note
- Display Note: OSTI as DE98007155