In-service motor performance diagnostics. Final CRADA report Page: 1 of 6
This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided to UNT Digital Library by the UNT Libraries Government Documents Department.
Extracted Text
The following text was automatically extracted from the image on this page using optical character recognition software:
Y/AMT-426
Y-12
Final CRADA Report
for
CRADA Number Y-1296-0422
IN-SERVICE MOTOR PERFORMANCE DIAGNOSTICS
S. L. Bunch
Lockheed Martin Energy Systems, Inc.
P. J. Otaduy
J. D. Kueck
R. H. Staunton
Lockheed Martin Energy Research, Corporation
Lawrence Bach
PdMA CorporationLV . S
0sI'April 15, 1997
Approved for Public Release;
distribution is unlimited.
D1STRIBUoN ias t OCUM- ULIIT ED
Prepared by the
Oak Ridge Y-12 Plant
managed by
LOCKHEED MARTIN ENERGY SYSTEMS, INC.
for the
U.S. DEPARTMENT OF ENERGY
under contract DE-AC05-840R21400
Upcoming Pages
Here’s what’s next.
Search Inside
This report can be searched. Note: Results may vary based on the legibility of text within the document.
Tools / Downloads
Get a copy of this page or view the extracted text.
Citing and Sharing
Basic information for referencing this web page. We also provide extended guidance on usage rights, references, copying or embedding.
Reference the current page of this Report.
Bunch, S. L.; Otaduy, P. J.; Kueck, J. D.; Staunton, R. H. & Bach, L. In-service motor performance diagnostics. Final CRADA report, report, April 15, 1997; Tennessee. (https://digital.library.unt.edu/ark:/67531/metadc708488/m1/1/: accessed April 23, 2024), University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu; crediting UNT Libraries Government Documents Department.