Panasonic dosimetry system performance testing and results at nuclear accident dose levels 500 rad to 10,000 rad

PDF Version Also Available for Download.

Description

Panasonic thermoluminescent dosimeters (TLDs) are used as the photon dose assessment part of the personal nuclear accident dosimeter (PNAD) and may be used for the same purpose with the fixed nuclear accident dosimeter (FNAD). To demonstrate compliance with 10CFR835.1304 (and, its predecessor, DOE Order 5480.11), several sets of dosimeters were irradiated to photon doses above the upper limit of the DOELAP testing standard, DOE/EH-0026 and DOE/EH-0027. The upper range of the test was 10,000 rads, using both low energy (70 keV) and high energy (662 keV and 1,332 keV) sources. The testing indicated that the Panasonic TLD system is capable ... continued below

Physical Description

10 p.

Creation Information

Klueber, M. R. April 6, 1998.

Context

This article is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. It has been viewed 18 times . More information about this article can be viewed below.

Who

People and organizations associated with either the creation of this article or its content.

Sponsors

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this article. Follow the links below to find similar items on the Digital Library.

Description

Panasonic thermoluminescent dosimeters (TLDs) are used as the photon dose assessment part of the personal nuclear accident dosimeter (PNAD) and may be used for the same purpose with the fixed nuclear accident dosimeter (FNAD). To demonstrate compliance with 10CFR835.1304 (and, its predecessor, DOE Order 5480.11), several sets of dosimeters were irradiated to photon doses above the upper limit of the DOELAP testing standard, DOE/EH-0026 and DOE/EH-0027. The upper range of the test was 10,000 rads, using both low energy (70 keV) and high energy (662 keV and 1,332 keV) sources. The testing indicated that the Panasonic TLD system is capable of meeting the requirements of 10CFR835.1304 and DOE Order 5480.11.

Physical Description

10 p.

Notes

INIS; OSTI as DE98005675

Source

  • 17. annual international Panasonic TLD users symposium, Santa Rosa, CA (United States), 8-12 Jun 1998

Language

Item Type

Identifier

Unique identifying numbers for this article in the Digital Library or other systems.

  • Other: DE98005675
  • Report No.: RFP--5189
  • Report No.: CONF-980661--
  • Grant Number: AC34-90DP62349
  • Office of Scientific & Technical Information Report Number: 672063
  • Archival Resource Key: ark:/67531/metadc708416

Collections

This article is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this article?

When

Dates and time periods associated with this article.

Creation Date

  • April 6, 1998

Added to The UNT Digital Library

  • Sept. 12, 2015, 6:31 a.m.

Description Last Updated

  • June 14, 2016, 9:22 p.m.

Usage Statistics

When was this article last used?

Yesterday: 0
Past 30 days: 1
Total Uses: 18

Interact With This Article

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Klueber, M. R. Panasonic dosimetry system performance testing and results at nuclear accident dose levels 500 rad to 10,000 rad, article, April 6, 1998; United States. (digital.library.unt.edu/ark:/67531/metadc708416/: accessed January 19, 2018), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.