Evaluation of heat sources and effect of dry out in single-shell tanks 241-SX-108 and 241-SX-114

PDF Version Also Available for Download.

Description

This report examines two tanks on the list of Single-Shell Tanks with high heat loads. This report assesses the maximum temperatures that might exist in the two tanks 241-SX-108 and 241-SX-114. In addition to assessing current conditions in the tanks, the effect of the drying out of the center of the tank on the maximum temperature in the waste and concrete was evaluated. A reassessment of the head loads was also done using more recent temperature and psychrometric data obtained from these two tanks.

Physical Description

27 p.

Creation Information

Ogden, D. M. December 16, 1996.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Author

Sponsor

Publisher

  • Westinghouse Hanford Company
    Publisher Info: Westinghouse Hanford Co., Richland, WA (United States)
    Place of Publication: Richland, Washington

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

This report examines two tanks on the list of Single-Shell Tanks with high heat loads. This report assesses the maximum temperatures that might exist in the two tanks 241-SX-108 and 241-SX-114. In addition to assessing current conditions in the tanks, the effect of the drying out of the center of the tank on the maximum temperature in the waste and concrete was evaluated. A reassessment of the head loads was also done using more recent temperature and psychrometric data obtained from these two tanks.

Physical Description

27 p.

Notes

OSTI as DE98059461

Source

  • Other Information: PBD: 16 Dec 1996

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Other: DE98059461
  • Report No.: WHC-SD-WM-ER--577
  • Grant Number: AC06-96RL13200
  • DOI: 10.2172/657795 | External Link
  • Office of Scientific & Technical Information Report Number: 657795
  • Archival Resource Key: ark:/67531/metadc708361

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • December 16, 1996

Added to The UNT Digital Library

  • Sept. 12, 2015, 6:31 a.m.

Description Last Updated

  • June 14, 2016, 3:09 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 1

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Ogden, D. M. Evaluation of heat sources and effect of dry out in single-shell tanks 241-SX-108 and 241-SX-114, report, December 16, 1996; Richland, Washington. (digital.library.unt.edu/ark:/67531/metadc708361/: accessed December 15, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.