Description

Focusing mirrors in 1 or 2 dimensions can be used to increase the intensity in a small-angle instrument while maintaining high resolution. Using the recently added toroidal mirror region type in MCLlB (Monte Carlo library for neutron instrument design), we compare five mirror shares: the ideal ellipsoid the tangent toroid, 8 tangent toroidal segments, 8 tangential cylindrical segments, and 20 tangential cylindrical segments. A small-angle scattering instrument on a spallation source was simulated to study resolution. Comparisons show that the ellipsoid provides superior resolution, but that the 8 tangential toroids are a good compromise. A resolution of 0.00056 {Angstrom}{sup -1}(rms), ... continued below

Physical Description

7 p.

Creation Information

Seeger, Philip A. December 31, 1997.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. It has been viewed 13 times . More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Sponsor

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

Focusing mirrors in 1 or 2 dimensions can be used to increase the intensity in a small-angle instrument while maintaining high resolution. Using the recently added toroidal mirror region type in MCLlB (Monte Carlo library for neutron instrument design), we compare five mirror shares: the ideal ellipsoid the tangent toroid, 8 tangent toroidal segments, 8 tangential cylindrical segments, and 20 tangential cylindrical segments. A small-angle scattering instrument on a spallation source was simulated to study resolution. Comparisons show that the ellipsoid provides superior resolution, but that the 8 tangential toroids are a good compromise. A resolution of 0.00056 {Angstrom}{sup -1}(rms), or (-)(+)11% at Q = 0.005 {Angstrom}{sup -1}, was achieved in the simulation using neutrons in the wavelength range 4-15 A. The count rate is high because the full area of the moderator is viewed.

Physical Description

7 p.

Notes

INIS; OSTI as DE98002671

Source

  • Materials research using cold neutrons at pulsed sources conference, Argonne, IL (United States), 25-26 Aug 1997

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Other: DE98002671
  • Report No.: LA-UR--97-4029
  • Report No.: CONF-9708115--
  • Grant Number: W-7405-ENG-36
  • DOI: 10.2172/659638 | External Link
  • Office of Scientific & Technical Information Report Number: 659638
  • Archival Resource Key: ark:/67531/metadc706663

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • December 31, 1997

Added to The UNT Digital Library

  • Sept. 12, 2015, 6:31 a.m.

Description Last Updated

  • May 20, 2016, 5:57 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 13

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

International Image Interoperability Framework

IIF Logo

We support the IIIF Presentation API

Seeger, Philip A. Using the MCLIB Library: Small-Angle Instrument with Focusing-Mirror Collimation, report, December 31, 1997; New Mexico. (digital.library.unt.edu/ark:/67531/metadc706663/: accessed October 18, 2018), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.