Safety assessment for hot test of the light duty utility arm in Hanford tank 241-T-106

PDF Version Also Available for Download.

Description

This safety assessment describes the proposed initial test of the Light Duty Utility Arm (LDUA), as it relates to the Tank Farms authorization basis and the previously analyzed safety basis.The LDUA will be tested in tank 241-T-106. A companion document(not included as part of the safety assessment), USQ Evaluation TF-96-0171, concludes that the test of the LDUA in tank 241-T-106 is within the current Tank Farms authorization basis. The conclusions of the safety assessment show that the test can be performed safely, using presently implemented controls.

Physical Description

106 p.

Creation Information

Heubach, E. C. June 28, 1996.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Sponsor

Publisher

  • Westinghouse Hanford Company
    Publisher Info: Westinghouse Hanford Co., Richland, WA (United States)
    Place of Publication: Richland, Washington

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

This safety assessment describes the proposed initial test of the Light Duty Utility Arm (LDUA), as it relates to the Tank Farms authorization basis and the previously analyzed safety basis.The LDUA will be tested in tank 241-T-106. A companion document(not included as part of the safety assessment), USQ Evaluation TF-96-0171, concludes that the test of the LDUA in tank 241-T-106 is within the current Tank Farms authorization basis. The conclusions of the safety assessment show that the test can be performed safely, using presently implemented controls.

Physical Description

106 p.

Notes

OSTI as DE98054303

Source

  • Other Information: PBD: 28 Jun 1996

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Other: DE98054303
  • Report No.: WHC-SD-WM-SAD--038
  • Grant Number: AC06-96RL13200
  • DOI: 10.2172/658856 | External Link
  • Office of Scientific & Technical Information Report Number: 658856
  • Archival Resource Key: ark:/67531/metadc705020

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • June 28, 1996

Added to The UNT Digital Library

  • Sept. 12, 2015, 6:31 a.m.

Description Last Updated

  • June 13, 2016, 8:51 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 2

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Heubach, E. C. Safety assessment for hot test of the light duty utility arm in Hanford tank 241-T-106, report, June 28, 1996; Richland, Washington. (digital.library.unt.edu/ark:/67531/metadc705020/: accessed December 17, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.