WHC-SD-W320-CSA-001 REV 0
CONTENTS
1.0 INTRODUCTION ... .... .. ...........-.-. 1-1
2.0 TANK 241-C-106 REMEDIATION PROGRAM .... . ........... 2-1
3.0 CHEMICAL CONSIDERATIONS - PLUTONIUM CONTAINING SOLIDS .. ..... 3-1
3.1 INTRODUCTION ...... . .............. 3-1
3.2 ADSORPTION ......... . ....... ....... 3-3
3.2.1 Formation Mechanisms .... . ........... 3-3
3.2.2 Composition of Solids and Sluicing Solutions ...... 3-6
3.2.3 Important Chemical Parameters . ........... 3-8
3.2.4 Plutonium/Absorber Ratios .. . ........... 3-8
3.3 SOLUBILITY ........ . ... ............ 3-13
3.4 SOLID-SOLID SOLUTION .. ...... .......... 3-17
3.5 EFFECTS OF AGING ........... . .......... 3-20
3.5.1 Adsorption ....... . .......... 3-20
3.5.2 Solubility ........ ... . .......... 3-21
4.0 PHYSICAL CONSIDERATIONS - SLUICING INDUCED SEPARATIONS .... ... 4-1
4.1 ONE-DIMENSIONAL SIMPLIFIED SETTLING SIMULATIONS .. ....... 4-1
4.1.1 Simplified Sedimentation Model . ...... ...... 4-1
4.1.2 Simulation Results ... ..... ........... 4-4
4.2 TWO-DIMENSIONAL ANALYTICAL MODELS .. ... ........... 4-6
4.3 THREE-DIMENSIONAL TEMPEST MODELING .. ........... 4-6
4.3.1 Tank 241-C-106 Pump Out Simulation .. ......... 4-7
4.3.2 Tank 241-AY-102 ........... ......... 4-8
4.4 OTHER EFFECTS ... ........ ......... 4-11
4.5 CONCLUSIONS FROM FLUID DYNAMIC MODELING .. . ......... 4-14
5.0 CRITICALITY CONSIDERATIONS FOR SLUICING . ............ 5-1
5.1 FISSILE MATERIAL CONCENTRATION . . ............ 5-1
5.2 DEFENSE IN DEPTH . ..... ........... ... . 5-4
5.2.1 Neutron Moderation 5-4
5.2.2 Areal Concentration Limit - =240 g Pu/ft2 (2600 g
Pu/in2).... .. ............... .. .. ...... .. .. ....5-5
5.2.3 Neutron Absorbers . .... . ......... ... 5-6
5.2.4 Geometry .......... ............ 5-8
5.3 PERSPECTIVE ON PLUTONIUM CONCENTRATION
WITHIN TANKS 241-C-106 AND 241-AY-102 . ... . ......... 5-8
6.0 CONCLUSIONS ... . .. . .. .......... .... 6-1
7.0 REFERENCES ......... ....... . ......... 7-1ix
Upcoming Pages
Here’s what’s next.
Search Inside
This report can be searched. Note: Results may vary based on the legibility of text within the document.
Tools / Downloads
Get a copy of this page or view the extracted text.
Citing and Sharing
Basic information for referencing this web page. We also provide extended guidance on usage rights, references, copying or embedding.
Reference the current page of this Report.
Waltar, A. E. Criticality safety assessment of tank 241-C-106 remediation, report, July 19, 1996; Richland, Washington. (https://digital.library.unt.edu/ark:/67531/metadc702698/m1/12/: accessed April 19, 2024), University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu; crediting UNT Libraries Government Documents Department.