Digital I&C systems in nuclear power plants. Risk-screening of environmental stressors and a comparison of hardware unavailability with an existing analog system

PDF Version Also Available for Download.

Description

In this report, we present a screening study to identify environmental stressors for digital instrumentation and control (I&C) systems in a nuclear power plant (NPP) which can be potentially risk-significant, and compare the hardware unavailability of such a system with that of its existing analog counterpart. The stressors evaluated are temperature, humidity, vibration, radiation, electro-magnetic interference (EMI), and smoke. The results of risk-screening for an example plant, subject to some bounding assumptions and based on relative changes in plant risk (core damage frequency impacts of the stressors), indicate that humidity, EMI from lightning, and smoke can be potentially risk-significant. Risk ... continued below

Physical Description

Medium: P; Size: 119 p.

Creation Information

Hassan, M. & Vesely, W. E. January 1998.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. It has been viewed 11 times . More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Sponsor

Publishers

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

In this report, we present a screening study to identify environmental stressors for digital instrumentation and control (I&C) systems in a nuclear power plant (NPP) which can be potentially risk-significant, and compare the hardware unavailability of such a system with that of its existing analog counterpart. The stressors evaluated are temperature, humidity, vibration, radiation, electro-magnetic interference (EMI), and smoke. The results of risk-screening for an example plant, subject to some bounding assumptions and based on relative changes in plant risk (core damage frequency impacts of the stressors), indicate that humidity, EMI from lightning, and smoke can be potentially risk-significant. Risk from other sources of EMI could not be evaluated for a lack of data. Risk from temperature appears to be insignificant as that from the assumed levels of vibrations. A comparison of the hardware unavailability of the existing analog Safety Injection Actuation System (SIAS) in the example plant with that of an assumed digital upgrade of the system indicates that system unavailability may be more sensitive to the level of redundancy in elements of the digital system than to the environmental and operational variations involved. The findings of this study can be used to focus activities relating to the regulatory basis for digital I&C upgrades in NPPs, including identification of dominant stressors, data-gathering, equipment qualification, and requirements to limit the effects of environmental stressors. 30 refs., 8 figs., 26 tabs.

Physical Description

Medium: P; Size: 119 p.

Notes

INIS; OSTI as TI98002675

Source

  • Other Information: PBD: Jan 1998

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Other: TI98002675
  • Report No.: NUREG/CR--6579
  • Report No.: BNL-NUREG--52536
  • Grant Number: AC02-76CH00016
  • DOI: 10.2172/574196 | External Link
  • Office of Scientific & Technical Information Report Number: 574196
  • Archival Resource Key: ark:/67531/metadc698334

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • January 1998

Added to The UNT Digital Library

  • Aug. 14, 2015, 8:43 a.m.

Description Last Updated

  • April 22, 2016, 6:55 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 11

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Hassan, M. & Vesely, W. E. Digital I&C systems in nuclear power plants. Risk-screening of environmental stressors and a comparison of hardware unavailability with an existing analog system, report, January 1998; Washington D.C.. (digital.library.unt.edu/ark:/67531/metadc698334/: accessed December 17, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.